The DOI matches its Crossref record.
Accurate Doppler Radar Noncontact Vital Sign Detection Using the RELAX Algorithm
Abstract
We consider using a Doppler radar for accurate noncontact vital sign detection. The Doppler radar first captures and downconverts the wireless signal that is phase modulated by the physiological movements, and then identifies the human heartbeat and respiration rates by processing the baseband signal. When nonlinear Doppler phase modulation is employed to monitor vital signs without contact, one of the challenges that we encounter is the presence of undesired harmonic terms and intermodulations other than the sinusoids of interest. A spectral estimation algorithm is needed to accurately estimate the sinusoidal frequencies before identifying the heartbeat and respiration rates. The conventional periodogram cannot reliably separate the rich sinusoidal components since it suffers from smearing and leakage problems, particularly for the case of limited data samples. A parametric and cyclic optimization approach, referred to as the RELAX algorithm, is instead suggested to mitigate these difficulties. Both simulated and experimental results are provided to validate the superiority of using the RELAX algorithm for accurate noncontact vital sign detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Non-Invasive Detection of Moving and Stationary Human With WiFi
Wu, C., Yang, Z., Zhou, Z., Liu, X., Liu, Y., & Cao, J. (2015) · IEEE Journal on Selected Areas in Communications · doi:10.1109/jsac.2015.2430294 · Cited by 354
Contactless Respiration Monitoring Via Off-the-Shelf WiFi Devices
Liu, X., Cao, J., Tang, S., Wen, J., & Guo, P. (2016) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2015.2504935 · Cited by 273
Non-invasive respiration rate monitoring using a single COTS TX-RX pair
Kaltiokallio, O., Yigitler, H., Jantti, R., & Patwari, N. (2014) · IPSN-14 Proceedings of the 13th International Symposium on Information Processing in Sensor Networks · doi:10.1109/ipsn.2014.6846741 · Cited by 101
Metadata
- Authors
- Li, C., Ling, J., Li, J., & Lin, J.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2010-03
- Volume
- 59
- Issue
- 3
- Pages
- 687-695
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2145784584
- Cited by
- 176
- References
- 0
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accurate Doppler Radar Noncontact Vital Sign Detection Using the RELAX Algorithm. https://app.cochat.ai/papers/10.1109/tim.2009.2025986
- The paper
- Li, C., Ling, J., Li, J., & Lin, J. (2010). Accurate Doppler Radar Noncontact Vital Sign Detection Using the RELAX Algorithm. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2009.2025986
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.