The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Design of a Novel Efficient Human–Computer Interface: An Electrooculagram Based Virtual Keyboard
Abstract
The aim of this paper is to present the design and application of an electrooculogram (EOG) based on an efficient human-computer interface (HCI). Establishing an alternative channel without speaking and hand movements is important in increasing the quality of life for the handicapped. EOG-based systems are more efficient than electroencephalogram (EEG)-based systems in some cases. By using a realized virtual keyboard, it is possible to notify in writing the needs of the patient in a relatively short time. Considering the biopotential measurement pitfalls, the novel EOG-based HCI system allows people to successfully communicate with their environment by using only eye movements. Classifying horizontal and vertical EOG channel signals in an efficient interface is realized in this study. The new system is microcontroller based, with a common-mode rejection ratio of 88 dB, an electronic noise of 0.6 μV (p-p), and a sampling rate of 176 Hz. The nearest neighborhood algorithm is used to classify the signals, and the classification performance is 95%. The novel EOG-based HCI system allows people to successfully and economically communicate with their environment by using only eye movements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Brain oscillations control hand orthosis in a tetraplegic
Pfurtscheller, G., Guger, C., Müller, G., Krausz, G., & Neuper, C. (2000) · Neuroscience Letters · doi:10.1016/s0304-3940(00)01471-3 · Cited by 472
Cited by
Pu, X., Guo, H., Chen, J., Wang, X., Xi, Y., Hu, C., & Wang, Z. L. (2017) · Science Advances · doi:10.1126/sciadv.1700694 · Cited by 624
From contact electrification to triboelectric nanogenerators
Wang, Z. L. (2021) · Reports on Progress in Physics · doi:10.1088/1361-6633/ac0a50 · Cited by 553
RetractedIncreasing trend of wearables and multimodal interface for human activity monitoring: A review
Kumari, P., Mathew, L., & Syal, P. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.12.001 · Cited by 298
EEG-Based Brain-Computer Interfaces: A Thorough Literature Survey
Hwang, H.-J., Kim, S., Choi, S., & Im, C.-H. (2013) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2013.780869 · Cited by 257
Metadata
- Authors
- Usakli, A. B., & Gurkan, S.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2010-08
- Volume
- 59
- Issue
- 8
- Pages
- 2099-2108
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2146485236
- Cited by
- 198
- References
- 3
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design of a Novel Efficient Human–Computer Interface: An Electrooculagram Based Virtual Keyboard. https://app.cochat.ai/papers/10.1109/tim.2009.2030923
- The paper
- Usakli, A. B., & Gurkan, S. (2010). Design of a Novel Efficient Human–Computer Interface: An Electrooculagram Based Virtual Keyboard. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2009.2030923
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.