The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Signal Transmission by Galvanic Coupling Through the Human Body
Abstract
Galvanic coupling is a promising approach for wireless intrabody data transmission between sensors. Using the human body as a transmission medium for electrical signals becomes a novel data communication technique in biomedical monitoring systems. In this paper, special attention is given to the coupling of the current into the human body. Safety requirements have to be fulfilled, and optimal signal coupling is of essence. Therefore, different electrodes are compared. A test system offers up to 1 mA contact current modulated in the frequency range of 10 kHz to 1 MHz. The injected current is up to 20 times below the maximum allowed contact current. Such a low-current approach enables data communication that is more energy saving than other wireless technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
Cited by
A survey on wireless body area networks
Latré, B., Braem, B., Moerman, I., Blondia, C., & Demeester, P. (2011) · Wireless Networks · doi:10.1007/s11276-010-0252-4 · Cited by 1,099
A Survey on Intrabody Communications for Body Area Network Applications
Seyedi, M., Kibret, B., Lai, D. T. H., & Faulkner, M. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2254714 · Cited by 327
A Survey on Wireless Body Area Networks for eHealthcare Systems in Residential Environments
Ghamari, M., Janko, B., Sherratt, R., Harwin, W., Piechockic, R., & Soltanpur, C. (2016) · Sensors · doi:10.3390/s16060831 · Cited by 300
A Survey on Human-in-the-Loop Applications Towards an Internet of All
Nunes, D. S., Zhang, P., & Sa Silva, J. (2015) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2015.2398816 · Cited by 284
Miniature battery-free bioelectronics
Nair, V., Dalrymple, A. N., Yu, Z., Balakrishnan, G., Bettinger, C. J., Weber, D. J., Yang, K., & Robinson, J. T. (2023) · Science · doi:10.1126/science.abn4732 · Cited by 128
Metadata
- Authors
- Wegmueller, M. S., Oberle, M., Felber, N., Kuster, N., & Fichtner, W.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2010-04
- Volume
- 59
- Issue
- 4
- Pages
- 963-969
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2104929542
- Cited by
- 182
- References
- 1
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Signal Transmission by Galvanic Coupling Through the Human Body. https://app.cochat.ai/papers/10.1109/tim.2009.2031449
- The paper
- Wegmueller, M. S., Oberle, M., Felber, N., Kuster, N., & Fichtner, W. (2010). Signal Transmission by Galvanic Coupling Through the Human Body. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2009.2031449
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.