The DOI matches its Crossref record; the references it cites are not checked yet.
A Novel Dual-Slope Resistance-to-Digital Converter
Abstract
A dual-slope resistance-to-digital (DSRDC) converter that accepts the resistance of a single-element resistive-type sensor as input and provides a direct digital output proportional to the parameter being sensed by the resistive-type sensor is presented in this paper. A high level of linearity and accuracy is achieved since the output of the DSRDC is dictated only by the magnitudes of a pair of dc reference voltages and the transformation constant of the sensor. Sensitivity analysis shows that the effect of circuit parameter variations on the output is minimal. Simulation studies and test results obtained on a prototype establish the efficacy of the proposed scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
References 10 · Cited by 47
Research works printed but not linked: 12
- 10.1109/IMTC.2009.5168406 · DOI
- george, 2006, switched capacitor triple slope capacitance to digital converter, Circuits Devices and Systems IEE Proceedings-, 153, 148, 10.1049/ip-cds:20050176 · DOI
- 0, usb-6251user manual, 16-Bit 8-Channel 1 25MSa/s Data Acquisition Device
- 10.1109/IMTC.2005.1604150 · DOI
- 2008, Industrial Platinum Resistance Thermometers and Platinum Temperature Sensors
- 10.1109/TIM.1979.4314808 · DOI
- hnatek, 1988, A User's Handbook of D/A and A/D Converters
- mohan, 2009, direct digital converter for a single, active element resistive sensor, Proc IEEE I2MTC, 828
- 10.1109/IMTC.2007.379367 · DOI
- 10.1109/19.728781 · DOI
- 0, Data SheetMAX4680 1 25 Ohm Dual SPST CMOS Analog Switches
- doebelin, 2004, Measurement SystemsApplication and Design
Metadata
- Authors
- Mohan, N. M., George, B., & Kumar, V. J.
- Affiliations
- Indian Institute of Technology Madras (IN)
- University of Graz (AT)
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2010-05
- Volume
- 59
- Issue
- 5
- Pages
- 1013-1018
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2165515484
- Cited by
- 47
- References
- 10
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 6 · 2022: 4 · 2021: 3 · 2020: 4 · 2019: 4 · 2018: 4 · 2017: 6 · 2016: 6 · 2015: 2 · 2014: 2
- FWCI
- 0.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Instrumentation and Measurement (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Physics and Astronomy › Instrumentation › Sensor Technology and Measurement Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- resistive sensors, analog-to-digital conversion, linearity, sensitivity analysis, circuit parameter variation, sensor signal conditioning
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review