The DOI matches its Crossref record.
Detection and Classification of Power Quality Disturbances Using Sparse Signal Decomposition on Hybrid Dictionaries
Abstract
Several methods have been proposed for detection and classification of power quality (PQ) disturbances using wavelet, Hilbert transform, Gabor transform, Gabor-Wigner transform, S transform, and Hilbert-Haung transform. This paper presents a new method for detection and classification of single and combined PQ disturbances using a sparse signal decomposition (SSD) on overcomplete hybrid dictionary (OHD) matrix. The method first decomposes a PQ signal into detail and approximation signals using the proposed SSD technique with an OHD matrix containing impulse and sinusoidal elementary waveforms. The output detail signal adequately captures morphological features of transients (impulsive and oscillatory) and waveform distortions (harmonics and notching). Whereas the approximation signal contains PQ features of fundamental, flicker, dc-offset, and short- and long-duration variations (sags, swells, and interruptions). Thus, the required PQ features are extracted from the detail and approximation signals. Then, a hierarchical decision-tree algorithm is used for classification of single and combined PQ disturbances. The proposed method is tested using both synthetic and microgrid simulated PQ disturbances. Results demonstrate the accuracy and robustness of the method in detection and classification of single and combined PQ disturbances under noiseless and noisy conditions. The method can be easily expanded for compressed sensing based PQ monitoring networks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, S., & Chen, H. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.09.160 · Cited by 414
Achlerkar, P. D., Samantaray, S. R., & Sabarimalai Manikandan, M. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2626469 · Cited by 279
Self-citationKhokhar, S., Mohd Zin, A. A. B., Mokhtar, A. S. B., & Pesaran, M. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.068 · Cited by 262
Hyperspectral Image Classification via Multiple-Feature-Based Adaptive Sparse Representation
Fang, L., Wang, C., Li, S., & Benediktsson, J. A. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2664480 · Cited by 172
Power Quality Disturbance Classification based on Adaptive Compressed Sensing and Machine Learning
Cheng, L., Wu, Z., Xuanyuan, S., & Chang, H. (2020) · 2020 IEEE Green Technologies Conference(GreenTech) · doi:10.1109/greentech46478.2020.9289735 · Cited by 11
Metadata
- Authors
- Manikandan, M. S., Samantaray, S. R., & Kamwa, I.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2015-01
- Volume
- 64
- Issue
- 1
- Pages
- 27-38
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2019971481
- Cited by
- 195
- References
- 0
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection and Classification of Power Quality Disturbances Using Sparse Signal Decomposition on Hybrid Dictionaries. https://app.cochat.ai/papers/10.1109/tim.2014.2330493
- The paper
- Manikandan, M. S., Samantaray, S. R., & Kamwa, I. (2015). Detection and Classification of Power Quality Disturbances Using Sparse Signal Decomposition on Hybrid Dictionaries. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2014.2330493
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.