Compressed Sensing: A Simple Deterministic Measurement Matrix and a Fast Recovery Algorithm
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Compressed sensing (CS) is a technique that is suitable for compressing and recovering signals having sparse representations in certain bases. CS has been widely used to optimize the measurement process of bandwidth and power constrained systems like wireless body sensor network. The central issues with CS are the construction of measurement matrix and the development of recovery algorithm. In this paper, we propose a simple deterministic measurement matrix that facilitates the hardware implementation. To control the sparsity level of the signals, we apply a thresholding approach in the discrete cosine transform domain. We propose a fast and simple recovery algorithm that performs the proposed thresholding approach. We validate the proposed method by compressing and recovering electrocardiogram and electromyogram signals. We implement the proposed measurement matrix in a MSP-EXP430G2 LaunchPad development board. The simulation and experimental results show that the proposed measurement matrix has a better performance in terms of reconstruction quality compared with random matrices. Depending on the compression ratio, it improves the signal-to-noise ratio of the reconstructed signals from 6 to 20 dB. The obtained results also confirm that the proposed recovery algorithm is, respectively, 23 and 12 times faster than the orthogonal matching pursuit (OMP) and stagewise OMP algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,591
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639 · cited 1×
“[5] in 2006.”
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017 · cited 1×
“However, based on the knowledge that x is has a sparse representation with respect to a basis , the recovery process can be performed in two steps [16].”
BackgroundSignal Recovery From Random Measurements Via Orthogonal Matching Pursuit
Tropp, J. A., & Gilbert, A. C. (2007) · IEEE Transactions on Information Theory · doi:10.1109/tit.2007.909108 · Cited by 9,653 · cited 4×
“Indeed, when the measurement matrices are randomly drawn, Tropp and Gilbert [30] have shown that”
MethodInfluentialDecoding by Linear Programming
Candes, E. J., & Tao, T. (2005) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.858979 · Cited by 7,121
A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296 · cited 1×
“in real time to a medical or monitoring center via wireless links [1].”
BackgroundDonoho, D. L., Tsaig, Y., Drori, I., & Starck, J.-L. (2012) · IEEE Transactions on Information Theory · doi:10.1109/tit.2011.2173241 · Cited by 1,509 · cited 1×
“For example, stagewise OMP (StOMP) selects multiple columns per iteration to accelerate the recovery process [31].”
BackgroundCompressed Sensing for Real-Time Energy-Efficient ECG Compression on Wireless Body Sensor Nodes
Mamaghanian, H., Khaled, N., Atienza, D., & Vandergheynst, P. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2156795 · Cited by 701
Certifying the Restricted Isometry Property is Hard
Bandeira, A. S., Dobriban, E., Mixon, D. G., & Sawin, W. F. (2013) · IEEE Transactions on Information Theory · doi:10.1109/tit.2013.2248414 · Cited by 261 · cited 1×
“Unfortunately, this property is difficult to verify for a given matrix A [18].”
BackgroundECG data compression using cut and align beats approach and 2-D transforms
Lee, H., & Buckley, K. M. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.759056 · Cited by 160 · cited 1×
“It has also been used to compress the physiological signals such as EEG [27] or ECG [28].”
MethodEnergy-Aware Sensor Node Design With Its Application in Wireless Sensor Networks
Yan, R., Sun, H., & Qian, Y. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2245181 · Cited by 152 · cited 1×
“The challenges in such network are mainly: 1) the limited bandwidth available; 2) the low memory and the reduced computational capability of biosensors; and 3) the limited energy due to the use of a small battery [2].”
BackgroundElectrocardiographic Data Compression Via Orthogonal Transforms
Ahmed, N., Milne, P. J., & Harris, S. G. (1975) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1975.324469 · Cited by 144 · cited 1×
“nals in the low-frequency components, particularly for physiological signals like ECG [34] or EMG [35].”
BackgroundRTSP: An Accurate and Energy-Efficient Protocol for Clock Synchronization in WSNs
Akhlaq, M., & Sheltami, T. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2012.2232472 · Cited by 106 · cited 1×
“Data compression is not the only solution to reducing the power consumption; the use of power efficient media access or transmission protocols has been an alternative approach [3].”
BackgroundDeterministic Sensing Matrices Arising From Near Orthogonal Systems
Li, S., & Ge, G. (2014) · IEEE Transactions on Information Theory · doi:10.1109/tit.2014.2303973 · Cited by 103 · cited 2×
“We quantify the distortion between the original and recovered signals by measuring the signal-to-noise ratio (SNR) defined as follows [12]: SNR[ dB] = 20 log10 ‖x‖2 ‖x − x̃‖2 (12)”
BackgroundMethodApplications of Compressed Sensing for SAR Moving-Target Velocity Estimation and Image Compression
Khwaja, A. S., & Ma, J. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2011.2122190 · Cited by 87 · cited 1×
“Khwaja and Ma [7] applied CS in synthetic aperture radar to simplify the hardware implementation and to reduce the amount data.”
MethodFang, J., Li, J., Shen, Y., Li, H., & Li, S. (2014) · IEEE Signal Processing Letters · doi:10.1109/lsp.2014.2316004 · Cited by 84 · cited 1×
“The second issue is well investigated because many algorithms have been proposed [13], [14].”
BackgroundAn efficient and compact compressed sensing microsystem for implantable neural recordings
Zhang, J., Suo, Y., Mitra, S., Chin, S., Hsiao, S., Yazicioglu, R. F., Tran, T. D., & Etienne-Cummings, R. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2284254 · Cited by 74 · cited 1×
“approach is using dictionary learning algorithms to generate depending on the signal properties [24].”
MethodThe simplest measurement matrix for compressed sensing of natural images
He, Z., Ogawa, T., & Haseyama, M. (2010) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2010.5651800 · Cited by 66 · cited 2×
“1) Validation of the Proposed Measurement Matrix: The goal of this experiment is to provide some performance comparison between the proposed deterministic measurement matrix and random matrices: 1) Gaussian : φi, j ∈ N (0, 1/M); 2) BPBD [22].”
BackgroundSimple and Efficient Compressed Sensing Encoder for Wireless Body Area Network
Ravelomanantsoa, A., Rabah, H., & Rouane, A. (2014) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2014.2320393 · Cited by 64 · cited 1×
“In [10], we used CS to compress the signals from the biosensors of a WBSN.”
MethodSelf-citationImproved Iterative Curvelet Thresholding for Compressed Sensing and Measurement
Ma, J. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2049221 · Cited by 62 · cited 1×
“in [25].”
Compressed Sensing for Surface Characterization and Metrology
Ma, J. (2009) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2027744 · Cited by 48 · cited 1×
“Ma [6] introduced CS in surface metrology to reduce data acquisition.”
BackgroundOn the choice of an electromyogram data compression method
Guerrero, A. P., & Mailhes, C. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1997.757009 · Cited by 35
Vanishingly Sparse Matrices and Expander Graphs, With Application to Compressed Sensing
Bah, B., & Tanner, J. (2013) · IEEE Transactions on Information Theory · doi:10.1109/tit.2013.2274267 · Cited by 31 · cited 1×
“To overcome these limitations, sparse random matrices have been proposed [20].”
Background
Metadata
- Authors
- Ravelomanantsoa, A., Rabah, H., & Rouane, A.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2015-12
- Volume
- 64
- Issue
- 12
- Pages
- 3405-3413
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W1947282229
- Cited by
- 173
- References
- 24
- FWCI
- 10.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.