Wearable Device-Based System to Monitor a Driver’s Stress, Fatigue, and Drowsiness
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
This paper proposes a wearable device-based system to monitor the abnormal conditions of a driver, including stress, fatigue, and drowsiness. The system measures the motional and physiological information of the driver using the developed wearable device on the wrist. Preprocessing is used to distinguish the valid signal parts of the measured signals, because various noises can occur in wearable sensors. Features are extracted from the signal parts, and an optimal feature set is determined by an analysis of variance and a sequential floating forward selection algorithm. To classify the driver's state, a support vector machine-based classification method is used to obtain high generalization performance considering interdriver variance. Experiments were conducted on an indoor driving simulator, with 28 subjects, to gather data for each state. The classification accuracy was 98.43% for fivefold cross validation on the data. In a subject-independent test, the accuracy was 68.31% for the four states and 84.46% for the three states consisting of normal, stressed, and fatigued or drowsy states. Using the proposed system, the abnormal conditions of the driver can be detected and distinguished. This advantage contributes to safer and more comfortable driving. Furthermore, the utilization of the wearable device makes the system easy to use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of feature selection techniques in bioinformatics
Saeys, Y., Inza, I., & Larrañaga, P. (2007) · Bioinformatics · doi:10.1093/bioinformatics/btm344 · Cited by 5,244
Autonomic nervous system activity in emotion: a review
Kreibig, S. D. (2010) · Biological Psychology · doi:10.1016/j.biopsycho.2010.03.010 · Cited by 3,188 · cited 1×
“TEM is another cardiovascular measure, and ANS response can be monitored by its signal [21], [22].”
BackgroundFloating search methods in feature selection
Pudil, P., Novovičová, J., & Kittler, J. (1994) · Pattern Recognition Letters · doi:10.1016/0167-8655(94)90127-9 · Cited by 3,098
Detecting Stress During Real-World Driving Tasks Using Physiological Sensors
Healey, J. A., & Picard, R. W. (2005) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2005.848368 · Cited by 2,207 · cited 2×
“Healey and Picard [9] used 5-min-long electromyogram, electrocardiogram (ECG), respiration, and galvanic skin response (GSR) measurements to classify low, medium-, and high-stress conditions of drivers; the overall accuracy was >97% for 24 subjects.”
BackgroundIntroduction to Machine Learning
Yu, F. R., & He, Y. (2019) · SpringerBriefs in Electrical and Computer Engineering · doi:10.1007/978-3-030-10546-4_1 · Cited by 1,594
Detecting Driver Drowsiness Based on Sensors: A Review
Sahayadhas, A., Sundaraj, K., & Murugappan, M. (2012) · Sensors · doi:10.3390/s121216937 · Cited by 782 · cited 2×
“Furthermore, this method can detect a condition only after it begins to show on the face [7], [8].”
BackgroundMethodIntroduction to Machine Learning
Oladipupo, T. (2010) · New Advances in Machine Learning · doi:10.5772/9394 · Cited by 654
Which Is the Best Multiclass SVM Method? An Empirical Study
Duan, K.-B., & Keerthi, S. S. (2005) · Lecture Notes in Computer Science · doi:10.1007/11494683_28 · Cited by 578 · cited 1×
“Winner-takes-all (WTA) and max-wins voting (MWV) methods can be used to expand the SVM to a multiclass classifier [37], [38].”
MethodApplying neural network analysis on heart rate variability data to assess driver fatigue
Patel, M., Lal, S. K. L., Kavanagh, D., & Rossiter, P. (2011) · Expert Systems with Applications · doi:10.1016/j.eswa.2010.12.028 · Cited by 418 · cited 1×
“[11] used the spectral image of heart rate from ECG; the method achieved an overall accuracy of 90% for 12 subjects.”
MethodCamera as the instrument: the rising trend of vision based measurement
Shirmohammadi, S., & Ferrero, A. (2014) · IEEE Instrumentation & Measurement Magazine · doi:10.1109/mim.2014.6825388 · Cited by 380 · cited 1×
“method uses cameras and image processing to monitor the eyelid, head movement, and facial expression of the driver [5], [6].”
Method
Cited by
Jang, H., Sel, K., Kim, E., Kim, S., Yang, X., Kang, S., Ha, K.-H., Wang, R., Rao, Y., Jafari, R., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-34406-2 · Cited by 127
Self-citation
Metadata
- Authors
- Choi, M., Koo, G., Seo, M., & Kim, S. W.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2018-03
- Volume
- 67
- Issue
- 3
- Pages
- 634-645
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2778222790
- Cited by
- 174
- References
- 34
- FWCI
- 5.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wearable Device-Based System to Monitor a Driver’s Stress, Fatigue, and Drowsiness. https://app.cochat.ai/papers/10.1109/tim.2017.2779329
- The paper
- Choi, M., Koo, G., Seo, M., & Kim, S. W. (2018). Wearable Device-Based System to Monitor a Driver’s Stress, Fatigue, and Drowsiness. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2017.2779329
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.