Motion-Artifact Reduction in Capacitive Heart-Rate Measurements by Adaptive Filtering
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Electrocardiography (ECG) measurements are essential components in clinical diagnosis and monitoring. Conventional ECG measurements produce discomfort to the patients due to the use of gel and direct skin contact. Capacitive electrodes can measure ECG signals through an isolation layer; they are especially suitable for long-term ambulatory monitoring. However, capacitive ECG measurements are severely affected by motion artifacts (MAs) due to variable coupling distance. Adaptive filtering has been widely used for MA reduction in ECG measurements. Unfortunately, a reference signal recorded by additional sensors is required for the existing adaptive-filtering methods, limiting their applicability in ambulatory settings. In this paper on capacitive ECG recordings, a novel adaptivefiltering method is proposed for MA removal, where the reference signal is extracted from the power-line interference (PLI). PLI is particularly evident in a capacitive ECG due to unbalanced coupling capacitance. Along with MAs, electrode movement causes variations in the PLI amplitude. By demodulating the PLI, a reference signal reflecting variations in the coupling capacitance can be extracted for adaptive MA removal. The proposed method was evaluated both by simulations and real data and compared with the acceleration-based adaptive-filtering method. Comparable or higher ECG signal-to-noise ratio was achieved by the proposed method with a computational cost of 79 μs/iteration, indicating effective MA removal. The proposed method may, therefore, lead to improved analysis of capacitive ECG signals in ambulatory settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Understanding bland altman analysis
Giavarina, D. (2015) · Biochemia Medica · doi:10.11613/bm.2015.015 · Cited by 4,706
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · cited 1×
“The adaptive filter is designed such that the squared error |v̂o,ecg[n]|2 is minimized [29].”
MethodA comprehensive survey of wearable and wireless ECG monitoring systems for older adults
Baig, M. M., Gholamhosseini, H., & Connolly, M. J. (2013) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-1021-6 · Cited by 284
Cited by
Sun, W., Guo, Z., Yang, Z., Wu, Y., Lan, W., Liao, Y., Wu, X., & Liu, Y. (2022) · Sensors · doi:10.3390/s22207784 · Cited by 112
“The sponge layer reduces the electrode impedance with the skin by absorbing sweat while avoiding crosstalk and short circuits between adjacent electrodes caused by sweat.”
BackgroundSignal Artifacts and Techniques for Artifacts and Noise Removal
Islam, M. K., Rastegarnia, A., & Sanei, S. (2021) · Intelligent Systems Reference Library · doi:10.1007/978-3-030-54932-9_2 · Cited by 54
Design and applications of conductive polymers in wearable electrophysiological sensing
Zhou, N., Zhang, L., Cui, T., Wu, P., & Lei, Z. (2025) · Science China Technological Sciences · doi:10.1007/s11431-025-3114-6 · Cited by 14
Metadata
- Authors
- Xu, L., Rabotti, C., Zhang, Y., Ouzounov, S., Harpe, P. J. A., & Mischi, M.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2019-10
- Volume
- 68
- Issue
- 10
- Pages
- 4085-4093
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2905043871
- Cited by
- 44
- References
- 3
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Motion-Artifact Reduction in Capacitive Heart-Rate Measurements by Adaptive Filtering. https://app.cochat.ai/papers/10.1109/tim.2018.2884041
- The paper
- Xu, L., Rabotti, C., Zhang, Y., Ouzounov, S., Harpe, P. J. A., & Mischi, M. (2019). Motion-Artifact Reduction in Capacitive Heart-Rate Measurements by Adaptive Filtering. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2018.2884041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.