CoChat

Automatic Fault Diagnosis of Infrared Insulator Images Based on Image Instance Segmentation and Temperature Analysis

Wang, Bin, Dong, Ming, Ren, Ming, Wu, Zhanyu, Guo, Chenxi, Zhuang, Tianxin, Pischler, Oliver, Xie, Jiacheng · 2020 · IEEE Transactions on Instrumentation and Measurement
Cited by 195

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

As an onsite condition monitoring method, an infrared inspection can help to discover and analyze abnormal temperature increases in power equipment. For improving the efficiency of the onsite diagnosis of insulators in substations, this article proposes an automatic diagnosis method using instance segmentation and temperature analysis of infrared insulator images. For developing this method, thousands of infrared images from field inspection databases were collected to establish an annotated data set of insulator images. With the aid of the Mask R-convolutional neural network (CNN), it was possible to extract multiple insulators automatically in the infrared images. Transfer learning, as well as the dynamic learning rate algorithm, were then employed to realize the training process of Mask R-CNN with the annotated image data set. The result of the testing experiment showed that the mean Average Precision (mAP) of the model is 0.77, and the frame per second (FPS) is 5.07, which indicated great identification accuracy and computing speed of the proposed model. Next, function fitting was realized to extract the temperature distribution of each insulator. Finally, to evaluate the condition of each insulator, rules, which are based on the related standards, were established using machine language. This is the first time that the machine could independently realize fault analysis of multiple insulators in the infrared images, which is a great attempt to adapt the development of the Internet of Things and the tendency of predictive maintenance. Moreover, because of the universality of the model algorithm used, automatic infrared fault diagnosis for other power equipment could also be performed in a similar manner, which has significant potential applicability in the area of power equipment diagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tim.2020.2965635

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Wang, B., Dong, M., Ren, M., Wu, Z., Guo, C., Zhuang, T., Pischler, O., & Xie, J.
Venue
IEEE Transactions on Instrumentation and Measurement
Published
2020-08
Volume
69
Issue
8
Pages
5345-5355
ISSN
  • 0018-9456 (ISSN-L)
  • 1557-9662
OpenAlex
W3000301935
Cited by
195
References
4
FWCI
11.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.