The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Dual-Band Microwave Sensor Based on Planar Rectangular Cavity Loaded With Pairs of Improved Resonator for Differential Sensing Applications
Abstract
A dual-band sensor based on a planar rectangular cavity loaded with pairs of improved planar resonator is used to measure the permittivity difference of liquids with a small volume (2.5 ul). The planar cavity is connected by two microstrip transmission lines, constituting a two-port device with two branches. A pair of interdigital capacitor (IDC)-based split ring resonator (SRR) is coupled to the middle part of each branch. The distance between the IDC-SRRs is large, and their coupling can be neglected. Thus, two resonance frequencies are produced (4.15 GHz and 9.18 GHz). One frequency is generated from the resonance of the two IDC-based SRRs (4.15 GHz), whereas the other results from the coupling of the rectangular cavity and the two IDC-based SRRs (9.18 GHz). Frequency splitting is used to detect changes in the dielectric characteristics of the liquids. If the two branches (IDC-based SRRs) of the proposed sensor are placed on the same liquid, only two resonance frequencies are obtained. When two different liquids are loaded by the sensor, the resonance frequency will be split into four. A planar rectangular cavity is used instead of a splitter configuration to motivate the two IDC-SRRs. This novel design affords a dual-band miniaturized sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metamaterial-based microfluidic sensor for dielectric characterization
Withayachumnankul, W., Jaruwongrungsee, K., Tuantranont, A., Fumeaux, C., & Abbott, D. (2013) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2012.10.027 · Cited by 473
Flexible metamaterials for wireless strain sensing
Melik, R., Unal, E., Perkgöz, N. K., Puttlitz, C. M., & Demir, H. V. (2009) · Applied Physics Letters · doi:10.1063/1.3250175 · Cited by 139
Dielectric relaxation spectroscopy of 2-propanol–water mixtures
Sato, T., & Buchner, R. (2003) · The Journal of Chemical Physics · doi:10.1063/1.1543137 · Cited by 130
Asymmetric split-ring resonator-based biosensor for detection of label-free stress biomarkers
Lee, H., Lee, J., Choi, S., Jang, I., Choi, J.-S., & Jung, H. (2013) · Applied Physics Letters · doi:10.1063/1.4816440 · Cited by 77
Randomized resonant metamaterials for single-sensor identification of elastic vibrations
Jiang, T., Li, C., He, Q., & Peng, Z. (2020) · Nature Communications · doi:10.1038/s41467-020-15950-1 · Cited by 76
Al-Otaibi, S. A., Cui, Y., & Tentzeris, M. M. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2951172 · Cited by 70
Thin-film sensor based tip-shaped split ring resonator metamaterial for microwave application
He, X., Wang, Y., Wang, J., & Gui, T.-L. (2010) · Microsystem Technologies · doi:10.1007/s00542-010-1080-2 · Cited by 54
Metamaterial Inspired Radio Frequency-Based Touchpad Sensor System
Memon, M. U., Salim, A., Jeong, H., & Lim, S. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2908507 · Cited by 49
Chen, C.-J. (2014) · IEEE Transactions on Components Packaging and Manufacturing Technology · doi:10.1109/tcpmt.2013.2297377 · Cited by 39
The Design and Operation of Ultra-Sensitive and Tunable Radio-Frequency Interferometers
Cui, Y., & Wang, P. (2014) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2014.2366134 · Cited by 38
Cited by
A review of the application of deep learning in intelligent fault diagnosis of rotating machinery
Zhu, Z., Lei, Y., Qi, G., Chai, Y., Mazur, N., An, Y., & Huang, X. (2023) · Measurement · doi:10.1016/j.measurement.2022.112346 · Cited by 731
Wavelet transform for rotary machine fault diagnosis:10 years revisited
Yan, R., Shang, Z., Xu, H., Wen, J., Zhao, Z., Chen, X., & Gao, R. X. (2023) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2023.110545 · Cited by 294
Perera, Y. S., Ratnaweera, D. A. A. C., Dasanayaka, C. H., & Abeykoon, C. (2023) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2023.105988 · Cited by 286
Wang, H., Liu, Z., Peng, D., & Zuo, M. J. (2023) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2023.110314 · Cited by 270
Towards trustworthy machine fault diagnosis: A probabilistic Bayesian deep learning framework
Zhou, T., Han, T., & Droguett, E. L. (2022) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2022.108525 · Cited by 260
Metadata
- Authors
- Liu, W., Zhang, J., & Huang, K.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2021
- Volume
- 70
- Pages
- 1-8
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W3217560493
- Cited by
- 546
- References
- 10
- FWCI
- 28.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual-Band Microwave Sensor Based on Planar Rectangular Cavity Loaded With Pairs of Improved Resonator for Differential Sensing Applications. https://app.cochat.ai/papers/10.1109/tim.2021.3118090
- The paper
- Liu, W., Zhang, J., & Huang, K. (2021). Dual-Band Microwave Sensor Based on Planar Rectangular Cavity Loaded With Pairs of Improved Resonator for Differential Sensing Applications. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2021.3118090
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.