The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
A Novel Ultrasound Robot With Force/Torque Measurement and Control for Safe and Efficient Scanning
Open accessAbstract
Medical ultrasound is of increasing importance in medical diagnosis and intraoperative assistance and possesses great potential advantages when integrated with robotics. However, some concerns, including the operation efficiency, operation safety, image quality, and comfort of patients, remain after introducing robotics into medical ultrasound. In this paper, an ultrasound robot integrating a force control mechanism, force/torque measurement mechanism, and online adjustment method, is proposed to overcome the current limitations. The ultrasound robot can measure operating forces and torques, provide adjustable constant operating forces, eliminate great operating forces introduced by accidental operations, and achieve various scanning depths based on clinical requirements. The proposed ultrasound robot would potentially facilitate sonographers to find the targets quickly, improve operation safety and efficiency, and decrease patients' discomfort. Simulations and experiments were carried out to evaluate the performance of the ultrasound robot. Experimental results show that the proposed ultrasound robot is able to detect operating force in the z-direction and torques around the x- and y- directions with errors of 3.53% F.S., 6.68% F.S., and 6.11% F.S., respectively, maintain the constant operating force with errors of less than 0.57N, and achieve various scanning depths for target searching and imaging. This proposed ultrasound robot has good performance and would potentially be used in medical ultrasound.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SonoNet: Real-Time Detection and Localisation of Fetal Standard Scan Planes in Freehand Ultrasound
Baumgartner, C. F., Kamnitsas, K., Matthew, J., Fletcher, T. P., Smith, S., Koch, L. M., Kainz, B., & Rueckert, D. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2712367 · Cited by 416
Application of Ultrasound in Medicine
Carovac, A., Smajlovic, F., & Junuzovic, D. (2011) · Acta Informatica Medica · doi:10.5455/aim.2011.19.168-171 · Cited by 402
Evans, K., Roll, S., & Baker, J. (2009) · Journal of Diagnostic Medical Sonography · doi:10.1177/8756479309351748 · Cited by 169
Robotic ultrasound systems in medicine
Priester, A. M., Natarajan, S., & Culjat, M. O. (2013) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2013.2593 · Cited by 156
Sinclair, M. D., Baumgartner, C. F., Matthew, J., Bai, W., Cerrolaza, J. J., Li, Y., Smith, S., Knight, C. L., Kainz, B., Hajnal, J. V., et al. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512278 · Cited by 92
Self-citationUse of a Robotic Arm to Perform Remote Abdominal Telesonography
Arbeille, P. L., Capri, A., Ayoub, J., Kieffer, V., Georgescu, M. E., & Poisson, G. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.05.0469 · Cited by 83
Huang, Y., Xiao, W., Wang, C., Liu, H., Huang, R., & Sun, Z. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3064283 · Cited by 78
Automatic 3-D Imaging and Measurement of Human Spines With a Robotic Ultrasound System
Yang, C., Jiang, M., Chen, M., Fu, M., Li, J., & Huang, Q. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3085110 · Cited by 68
Design and Integration of a Parallel, Soft Robotic End-Effector for Extracorporeal Ultrasound
Lindenroth, L., Housden, R. J., Wang, S., Back, J., Rhode, K., & Liu, H. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2957609 · Cited by 59
Self-citationLi, K., Xu, Y., Wang, J., Ni, D., Liu, L., & Meng, M. Q. ‐. (2021) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2021.3127015 · Cited by 57
Cited by
Liu, D., Cui, L., & Cheng, W. (2024) · Measurement Science and Technology · doi:10.1088/1361-6501/acf390 · Cited by 256
Metadata
- Authors
- Bao, X., Wang, S., Zheng, L., Housden, R. J., Hajnal, J. V., & Rhode, K.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2023
- Volume
- 72
- Pages
- 1-12
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W4319996939
- Cited by
- 427
- References
- 17
- FWCI
- 31.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel Ultrasound Robot With Force/Torque Measurement and Control for Safe and Efficient Scanning. https://app.cochat.ai/papers/10.1109/tim.2023.3239925
- The paper
- Bao, X., Wang, S., Zheng, L., Housden, R. J., Hajnal, J. V., & Rhode, K. (2023). A Novel Ultrasound Robot With Force/Torque Measurement and Control for Safe and Efficient Scanning. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2023.3239925
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.