The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Regularization Parameter Selection for Nonlinear Iterative Image Restoration and MRI Reconstruction Using GCV and SURE-Based Methods
Open accessAbstract
Regularized iterative reconstruction algorithms for imaging inverse problems require selection of appropriate regularization parameter values. We focus on the challenging problem of tuning regularization parameters for nonlinear algorithms for the case of additive (possibly complex) Gaussian noise. Generalized cross-validation (GCV) and (weighted) mean-squared error (MSE) approaches (based on Steinfs Unbiased Risk Estimate. SURE) need the Jacobian matrix of the nonlinear reconstruction operator (representative of the iterative algorithm) with respect to the data. We derive the desired Jacobian matrix for two types of nonlinear iterative algorithms: a fast variant of the standard iterative reweighted least-squares method and the contemporary split-Bregman algorithm, both of which can accommodate a wide variety of analysis- and synthesis-type regularizers. The proposed approach iteratively computes two weighted SURE-type measures: Predicted-SURE and Projected-SURE (that require knowledge of noise variance Ð2), and GCV (that does not need Ð2) for these algorithms. We apply the methods to image restoration and to magnetic resonance image (MRI) reconstruction using total variation (TV) and an analysis-type .1-regularization. We demonstrate through simulations and experiments with real data that minimizing Predicted-SURE and Projected-SURE consistently lead to near-MSE-optimal reconstructions. We also observed that minimizing GCV yields reconstruction results that are near-MSE-optimal for image restoration and slightly suboptimal for MRI. Theoretical derivations in this work related to Jacobian matrix evaluations can be extended, in principle, to other types of regularizers and reconstruction algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huber, P. J. (1981) · Wiley Series in Probability and Statistics · doi:10.1002/0471725250 · Cited by 7,066
Spline Models for Observational Data
Wahba, G. (1990) · doi:10.1137/1.9781611970128 · Cited by 4,184
Analysis of Discrete Ill-Posed Problems by Means of the L-Curve
Hansen, P. C. (1992) · SIAM Review · doi:10.1137/1034115 · Cited by 3,903
Craven, P., & Wahba, G. (1978) · Numerische Mathematik · doi:10.1007/bf01404567 · Cited by 3,388
A New Alternating Minimization Algorithm for Total Variation Image Reconstruction
Wang, Y., Yang, J., Yin, W., & Zhang, Y. (2008) · SIAM Journal on Imaging Sciences · doi:10.1137/080724265 · Cited by 1,975
A New SURE Approach to Image Denoising: Interscale Orthonormal Wavelet Thresholding
Luisier, F., Blu, T., & Unser, M. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.891064 · Cited by 623
A stochastic estimator of the trace of the influence matrix for laplacian smoothing splines
Hutchinson, M. F. (1990) · Communications in Statistics - Simulation and Computation · doi:10.1080/03610919008812866 · Cited by 610
Cited by
Tensor-Based Formulation and Nuclear Norm Regularization for Multienergy Computed Tomography
Semerci, O., Hao, N., Kilmer, M. E., & Miller, E. L. (2014) · IEEE Transactions on Image Processing · doi:10.1109/tip.2014.2305840 · Cited by 389
Deep Magnetic Resonance Image Reconstruction: Inverse Problems Meet Neural Networks
Liang, D., Cheng, J., Ke, Z., & Ying, L. (2020) · IEEE Signal Processing Magazine · doi:10.1109/msp.2019.2950557 · Cited by 370
Yaman, B., Hosseini, S. A. H., Moeller, S., Ellermann, J., Uğurbil, K., & Akçakaya, M. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28378 · Cited by 327
Kessler, L. G., Barnhart, H. X., Buckler, A. J., Choudhury, K. R., Kondratovich, M. V., Toledano, A., Guimaraes, A. R., Filice, R., Zhang, Z., Sullivan, D. C., et al. (2015) · Statistical Methods in Medical Research · doi:10.1177/0962280214537333 · Cited by 293
Metadata
- Authors
- Ramani, S., Liu, Z., Rosen, J., Nielsen, J., & Fessler, J. A.
- Venue
- IEEE Transactions on Image Processing
- Published
- 2012-08
- Volume
- 21
- Issue
- 8
- Pages
- 3659-3672
- ISSN
- 1057-7149 (ISSN-L)
- 1941-0042
- OpenAlex
- W1993102688
- Cited by
- 231
- References
- 7
- FWCI
- 16.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.