The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Dequantizing Compressed Sensing: When Oversampling and Non-Gaussian Constraints Combine
Open accessAbstract
In this paper, we study the problem of recovering sparse or compressible signals from uniformly quantized measurements. We present a new class of convex optimization programs, or decoders, coined Basis Pursuit DeQuantizer of moment p (BPDQp), that model the quantization distortion more faithfully than the commonly used Basis Pursuit DeNoise (BPDN) program. Our decoders proceed by minimizing the sparsity of the signal to be reconstructed subject to a data-fidelity constraint expressed in the ℓp-norm of the residual error for 2 ≤ p ≤ ∞. We show theoretically that, (i) the reconstruction error of these new decoders is bounded if the sensing matrix satisfies an extended Restricted Isometry Property involving the Iρ norm, and (ii), for Gaussian random matrices and uniformly quantized measurements, BPDQpperformance exceeds that of BPDN by dividing the reconstruction error due to quantization by √(p + 1). This last effect happens with high probability when the number of measurements exceeds a value growing with p, i.e., in an oversampled situation compared to what is commonly required by BPDN = BPDQ2. To demonstrate the theoretical power of BPDQp, we report numerical simulations on signal and image reconstruction problems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
A New Alternating Minimization Algorithm for Total Variation Image Reconstruction
Wang, Y., Yang, J., Yin, W., & Zhang, Y. (2008) · SIAM Journal on Imaging Sciences · doi:10.1137/080724265 · Cited by 1,975
Cited by
Deep Learning for Intelligent Wireless Networks: A Comprehensive Survey
Mao, Q., Hu, F., & Hao, Q. (2018) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2018.2846401 · Cited by 789
Compressive Sensing in Electromagnetics - A Review
Massa, A., Rocca, P., & Oliveri, G. (2015) · IEEE Antennas and Propagation Magazine · doi:10.1109/map.2015.2397092 · Cited by 360
Compressed Sensing With Quantized Measurements
Zymnis, A., Boyd, S., & Candes, E. (2010) · IEEE Signal Processing Letters · doi:10.1109/lsp.2009.2035667 · Cited by 316
Metadata
- Authors
- Jacques, L., Hammond, D. K., & Fadili, J. M.
- Venue
- IEEE Transactions on Information Theory
- Published
- 2011-01
- Volume
- 57
- Issue
- 1
- Pages
- 559-571
- ISSN
- 0018-9448 (ISSN-L)
- 1557-9654
- OpenAlex
- W2128804753
- Cited by
- 213
- References
- 2
- FWCI
- 18.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dequantizing Compressed Sensing: When Oversampling and Non-Gaussian Constraints Combine. https://app.cochat.ai/papers/10.1109/tit.2010.2093310
- The paper
- Jacques, L., Hammond, D. K., & Fadili, J. M. (2011). Dequantizing Compressed Sensing: When Oversampling and Non-Gaussian Constraints Combine. IEEE Transactions on Information Theory. https://doi.org/10.1109/tit.2010.2093310
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.