Incremental Diagnosis Method for Intelligent Wearable Sensor Systems
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This paper presents an incremental diagnosis method (IDM) to detect a medical condition with the minimum wearable sensor usage by dynamically adjusting the sensor set based on the patient's state in his/her natural environment. The IDM, comprised of a naive Bayes classifier generated by supervised training with Gaussian clustering, is developed to classify patient motion in-context (due to a medical condition) and in real-time using a wearable sensor system. The IDM also incorporates a utility function, which is a simple form of expert knowledge and user preferences in sensor selection. Upon initial in-context detection, the utility function decides which sensor is to be activated next. High-resolution in-context detection with minimum sensor usage is possible because the necessary sensor can be activated or requested at the appropriate time. As a case study, the IDM is demonstrated in detecting different severity levels of a limp with minimum usage of high diagnostic resolution sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Friedman, N., Geiger, D., & Goldszmidt, M. (1997) · Machine Learning · doi:10.1023/a:1007465528199 · Cited by 4,742
Activity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147 · cited 1×
“As a result, three more data sets (left knee sensor data set to zero, right knee sensor data set to zero, and both knee sensors set to zero) were created from the original test data collection.”
BackgroundAMON: A Wearable Multiparameter Medical Monitoring and Alert System
Anliker, U., Ward, J. A., Lukowicz, P., Troster, G., Dolveck, F., Baer, M., Keita, F., Schenker, E. B., Catarsi, F., Coluccini, L., et al. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.837888 · Cited by 707 · cited 1×
“The proposed method minimizes the set of activated sensors by choosing only appropriate sensors as needed.”
MethodHealth monitoring in the home of the future
Korhonen, I., Parkka, J., & Van Gils, M. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213628 · Cited by 486 · cited 2×
“Wearable systems should interface with and use the data provided by these instruments [6]—a capability not enabled in many wearable systems.”
A Reliable Gyroscope-Based Gait-Phase Detection Sensor Embedded in a Shoe Insole
Pappas, I. P. I., Keller, T., Mangold, S., Popovic, M., Dietz, V., & Morari, M. (2004) · IEEE Sensors Journal · doi:10.1109/jsen.2004.823671 · Cited by 221 · cited 1×
“Limp detection is chosen as a case study because a limp is a visually observable symptom that can be detected by context recognition methods using noninvasive sensors [5], [12], [22]–[24].”
Cited by
Wearable Sensors for Human Activity Monitoring: A Review
Mukhopadhyay, S. C. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2370945 · Cited by 1,401
Activity identification using body-mounted sensors—a review of classification techniques
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., Howard, D., Meijer, K., & Crompton, R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/r01 · Cited by 600
Comparative study on classifying human activities with miniature inertial and magnetic sensors
Altun, K., Barshan, B., & Tunçel, O. (2010) · Pattern Recognition · doi:10.1016/j.patcog.2010.04.019 · Cited by 564
Barshan, B., & Yuksek, M. C. (2014) · The Computer Journal · doi:10.1093/comjnl/bxt075 · Cited by 346
The Promise of mHealth: Daily Activity Monitoring and Outcome Assessments by Wearable Sensors
Dobkin, B. H., & Dorsch, A. (2011) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968311425908 · Cited by 291
Human Activity Recognition Using Inertial/Magnetic Sensor Units
Altun, K., & Barshan, B. (2010) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-14715-9_5 · Cited by 279
Caramia, C., Torricelli, D., Schmid, M., Munoz-Gonzalez, A., Gonzalez-Vargas, J., Grandas, F., & Pons, J. L. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2865218 · Cited by 243
An Unsupervised Approach for Automatic Activity Recognition Based on Hidden Markov Model Regression
Trabelsi, D., Mohammed, S., Chamroukhi, F., Oukhellou, L., & Amirat, Y. (2013) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2013.2256349 · Cited by 172
Real-time analysis of physiological data to support medical applications
Apiletti, D., Baralis, E., Bruno, G., & Cerquitelli, T. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2010702 · Cited by 87
Metadata
- Authors
- Wu, W. H., Bui, A. A. T., Batalin, M. A., Liu, D., & Kaiser, W. J.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2007-09
- Volume
- 11
- Issue
- 5
- Pages
- 553-562
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2096886535
- Cited by
- 63
- References
- 5
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.