CoChat

Incremental Diagnosis Method for Intelligent Wearable Sensor Systems

Wu, Winston H., Bui, Alex A. T., Batalin, Maxim A., Liu, Duo, Kaiser, William J. · 2007 · IEEE Transactions on Information Technology in Biomedicine
Cited by 63

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

This paper presents an incremental diagnosis method (IDM) to detect a medical condition with the minimum wearable sensor usage by dynamically adjusting the sensor set based on the patient's state in his/her natural environment. The IDM, comprised of a naive Bayes classifier generated by supervised training with Gaussian clustering, is developed to classify patient motion in-context (due to a medical condition) and in real-time using a wearable sensor system. The IDM also incorporates a utility function, which is a simple form of expert knowledge and user preferences in sensor selection. Upon initial in-context detection, the utility function decides which sensor is to be activated next. High-resolution in-context detection with minimum sensor usage is possible because the necessary sensor can be activated or requested at the appropriate time. As a case study, the IDM is demonstrated in detecting different severity levels of a limp with minimum usage of high diagnostic resolution sensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/titb.2007.897579

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Wu, W. H., Bui, A. A. T., Batalin, M. A., Liu, D., & Kaiser, W. J.
Venue
IEEE Transactions on Information Technology in Biomedicine
Published
2007-09
Volume
11
Issue
5
Pages
553-562
ISSN
1089-7771 (ISSN-L)
OpenAlex
W2096886535
Cited by
63
References
5
FWCI
7.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.