A Healthcare Integration System for Disease Assessment and Safety Monitoring of Dementia Patients
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Elderly dementia patients often get lost due to lack of a sense of direction. This may put them at risk and cause their families much worry. The goal of this study is to use information technology to enhance the professional judgment of caregivers, strengthen internal safety monitoring at care organizations, and improve the quality of care for dementia patients. An eXtensible-Markup-Language-based dementia assessment system combining program code and assessment content is used to provide caregivers with better flexibility and real-time response ability. Beyond establishing long-term case files, the system can also perform data consistency analysis, strengthen caregivers' continuing education, improve caregivers' case judgment skills, and reduce the incidence of accidents due to neglect. This study also applies radio frequency identification (RFID) technology to the development of an indoor and outdoor active safety monitoring mechanism. The system can automatically remind caregivers whenever an elderly person approaches a dangerous area or strays too far. Apart from the use of different size tags, the realization of the system also employs the tame transformation signatures (TTS) algorithm to encrypt tag IDs and protect personal privacy. Clinical testing of the system showed that the indoor RFID reader has a response time of 0.5 s when sensing 40 tags, while the outdoor reader has a sensing time of approximately 5 s due to the need to save power. In the latter case, the system can ensure that elderly patients stay less than 15 m away from their caregivers. Patients were relatively willing to wear light tags. We also found that irritable patients with strong mobility were less compliant and often removed their own tags. Caregivers must provide active care and adopt various safety measures to protect the type of patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Clinical Scale for the Staging of Dementia
Hughes, C. P., Berg, L., Danziger, W., Coben, L. A., & Martin, R. L. (1982) · British Journal of Psychiatry · doi:10.1192/bjp.140.6.566 · Cited by 7,056 · cited 1×
“The SCDR form contains 81 questions taken from CDR [16], activities of daily living (ADL) [17], and instrument activities of daily living (IADL) [18].”
BackgroundRFID security and privacy: a research survey
Juels, A. (2006) · IEEE Journal on Selected Areas in Communications · doi:10.1109/jsac.2005.861395 · Cited by 1,911
AMON: A Wearable Multiparameter Medical Monitoring and Alert System
Anliker, U., Ward, J. A., Lukowicz, P., Troster, G., Dolveck, F., Baer, M., Keita, F., Schenker, E. B., Catarsi, F., Coluccini, L., et al. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.837888 · Cited by 707 · cited 1×
“These modules can record the elder’s everyday living habits [10] and detect any physiological or behavioral abnormalities.”
BackgroundIncidence of dementia and probable Alzheimer's disease in a general population: The Framingham Study
Bachman, D. L., Wolf, P. A., Linn, R. T., Knoefel, J. E., Cobb, J. L., Belanger, A. J., White, L. R., & D'Agostino, R. B. (1993) · Neurology · doi:10.1212/wnl.43.3_part_1.515 · Cited by 470
Mihailidis, A., Carmichael, B., & Boger, J. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.834386 · Cited by 208 · cited 1×
“In addition, high-tech systems can use visual or auditory signals to provide the elder with many types of daily reminders [6], [7], enabling them to live independently and safely [8].”
BackgroundBehavioral and Psychologic Symptoms in Different Types of Dementia
Chiu, M.-J., Chen, T.-F., Yip, P.-K., Hua, M.-S., & Tang, L.-Y. (2006) · Journal of the Formosan Medical Association · doi:10.1016/s0929-6646(09)60150-9 · Cited by 136 · cited 1×
“Many dementia researchers and research centers designed various forms intended to assess degree of dementia on the basis of symptoms [14], [15].”
Background
Cited by
Smart health monitoring systems: An overview of design and modeling
Baig, M. M., & Gholamhosseini, H. (2013) · Journal of Medical Systems · doi:10.1007/s10916-012-9898-z · Cited by 396
The Adoption and Implementation of RFID Technologies in Healthcare: A Literature Review
Yao, W., Chu, C.-H., & Li, Z. (2012) · Journal of Medical Systems · doi:10.1007/s10916-011-9789-8 · Cited by 289
A comprehensive survey of wearable and wireless ECG monitoring systems for older adults
Baig, M. M., Gholamhosseini, H., & Connolly, M. J. (2013) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-1021-6 · Cited by 284
Sapci, A. H., & Sapci, H. A. (2019) · JMIR Aging · doi:10.2196/15429 · Cited by 202
“Multimedia Appendix 1 lists the characteristics and highlights of the included studies [6-86].”
BackgroundDetection of falls among the elderly by a floor sensor using the electric near field
Rimminen, H., Lindstrom, J., Linnavuo, M., & Sepponen, R. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2051956 · Cited by 172
“Fall detectors worn by the user produce outstanding results [5], but the batteries must be charged frequently and some irritable patients will remove such devices [6].”
Background
Metadata
- Authors
- Lin, C.-C., Lin, P.-Y., Lu, P.-K., Hsieh, G.-Y., Lee, W.-L., & Lee, R.-G.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2008-09
- Volume
- 12
- Issue
- 5
- Pages
- 579-586
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2116512314
- Cited by
- 123
- References
- 6
- FWCI
- 22.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.