ECG Signal Compression and Classification Algorithm With Quad Level Vector for ECG Holter System
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
An ECG signal processing method with quad level vector (QLV) is proposed for the ECG holter system. The ECG processing consists of the compression flow and the classification flow, and the QLV is proposed for both flows to achieve better performance with low-computation complexity. The compression algorithm is performed by using ECG skeleton and the Huffman coding. Unit block size optimization, adaptive threshold adjustment, and 4-bit-wise Huffman coding methods are applied to reduce the processing cost while maintaining the signal quality. The heartbeat segmentation and the R-peak detection methods are employed for the classification algorithm. The performance is evaluated by using the Massachusetts Institute of Technology-Boston's Beth Israel Hospital Arrhythmia Database, and the noise robust test is also performed for the reliability of the algorithm. Its average compression ratio is 16.9:1 with 0.641% percentage root mean square difference value and the encoding rate is 6.4 kbps. The accuracy performance of the R-peak detection is 100% without noise and 95.63% at the worst case with -10-dB SNR noise. The overall processing cost is reduced by 45.3% with the proposed compression techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Technique for High-Performance Data Compression
Welch (1984) · Computer · doi:10.1109/mc.1984.1659158 · Cited by 2,182
Automatic Classification of Heartbeats Using ECG Morphology and Heartbeat Interval Features
deChazal, P., O'Dwyer, M., & Reilly, R. B. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827359 · Cited by 1,671
A patient-adaptable ECG beat classifier using a mixture of experts approach
Hu, Y. H., Palreddy, S., & Tompkins, W. J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623058 · Cited by 614
The use of the Hilbert transform in ECG signal analysis
Benitez, D., Gaydecki, P. A., Zaidi, A., & Fitzpatrick, A. P. (2001) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(01)00009-9 · Cited by 489
Wavelet and wavelet packet compression of electrocardiograms
Hilton, M. L. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.568915 · Cited by 415
Jabaudon, D., Sztajzel, J., Sievert, K., Landis, T., & Sztajzel, R. (2004) · Stroke · doi:10.1161/01.str.0000131269.69502.d9 · Cited by 414
Analysis of First-Derivative Based QRS Detection Algorithms
Arzeno, N. M., Deng, Z.-D., & Poon, C.-S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912658 · Cited by 413 · cited 3×
“Table IV shows the R-peak detection accuracy performance and the comparison with the previous works [ 25 ], [28]‐[30], and we can see that the performance of this work is better than the others.”
BackgroundMethodResultInfluentialThe weighted diagnostic distortion (WDD) measure for ECG signal compression
Zigei, Y., Cohen, A., & Katz, A. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2000.880093 · Cited by 405
AZTEC, a Preprocessing Program for Real-Time ECG Rhythm Analysis
Cox, J. R., Nolle, F. M., Fozzard, H. A., & Oliver, G. C. (1968) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1968.4502549 · Cited by 367
A New Data-Reduction Algorithm for Real-Time ECG Analysis
Abenstein, J. P., & Tompkins, W. J. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324962 · Cited by 269
Cited by
ECG-based heartbeat classification for arrhythmia detection: A survey
Luz, E. J. D. S., Schwartz, W. R., Cámara-Chávez, G., & Menotti, D. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.12.008 · Cited by 878
Kaplan Berkaya, S., Uysal, A. K., Sora Gunal, E., Ergin, S., Gunal, S., & Gulmezoglu, M. B. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.03.003 · Cited by 610
A comprehensive survey of wearable and wireless ECG monitoring systems for older adults
Baig, M. M., Gholamhosseini, H., & Connolly, M. J. (2013) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-1021-6 · Cited by 284
A Configurable and Low-Power Mixed Signal SoC for Portable ECG Monitoring Applications
Kim, H., Kim, S., Van Helleputte, N., Artes, A., Konijnenburg, M., Huisken, J., Van Hoof, C., & Yazicioglu, R. F. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2260159 · Cited by 230
“2) Beat detection: the QRS complex is detected using a derivative-based algorithm [7] or low-power beat detection algorithm with band-power extraction channel [1].”
MethodSelf-citationElgendi, M., Eskofier, B., Dokos, S., & Abbott, D. (2014) · PLoS ONE · doi:10.1371/journal.pone.0084018 · Cited by 222
“[143] who developed a simple algorithm to detect QRS complexes for Holter devices.”
Metadata
- Authors
- Kim, H., Yazicioglu, R. F., Merken, P., Van Hoof, C., & Yoo, H.-J.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2010-01
- Volume
- 14
- Issue
- 1
- Pages
- 93-100
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2143698637
- Cited by
- 169
- References
- 17
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ECG Signal Compression and Classification Algorithm With Quad Level Vector for ECG Holter System. https://app.cochat.ai/papers/10.1109/titb.2009.2031638
- The paper
- Kim, H., Yazicioglu, R. F., Merken, P., Van Hoof, C., & Yoo, H.-J. (2010). ECG Signal Compression and Classification Algorithm With Quad Level Vector for ECG Holter System. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/titb.2009.2031638
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.