Equipment Location in Hospitals Using RFID-Based Positioning System
The DOI matches its Crossref record.
Abstract
Throughout various complex processes within hospitals, context-aware services and applications can help to improve the quality of care and reduce costs. For example, sensors and radio frequency identification (RFID) technologies for e-health have been deployed to improve the flow of material, equipment, personal, and patient. Bed tracking, patient monitoring, real-time logistic analysis, and critical equipment tracking are famous applications of real-time location systems (RTLS) in hospitals. In fact, existing case studies show that RTLS can improve service quality and safety, and optimize emergency management and time critical processes. In this paper, we propose a robust system for position and orientation determination of equipment. Our system utilizes passive (RFID) technology mounted on flooring plates and several peripherals for sensor data interpretation. The system is implemented and tested through extensive experiments. The results show that our system's average positioning and orientation measurement outperforms existing systems in terms of accuracy. The details of the system as well as the experimental results are presented in this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
An IoT-Aware Architecture for Smart Healthcare Systems
Catarinucci, L., de Donno, D., Mainetti, L., Palano, L., Patrono, L., Stefanizzi, M. L., & Tarricone, L. (2015) · IEEE Internet of Things Journal · doi:10.1109/jiot.2015.2417684 · Cited by 1,167
“In case of emergency send push notification to respective doctor.”
BackgroundMobile-health: A review of current state in 2015
Silva, B. M. C., Rodrigues, J. J. P. C., de la Torre Díez, I., López-Coronado, M., & Saleem, K. (2015) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2015.06.003 · Cited by 871
Illuminating the dark spaces of healthcare with ambient intelligence
Haque, A., Milstein, A., & Fei-Fei, L. (2020) · Nature · doi:10.1038/s41586-020-2669-y · Cited by 274
“Unfortunately, RFID provides coarse location estimates (that is, within tens of centimetres 35 ), making it unable to categorize fine-grained movements such as the WHO’s five moments of hand hygiene 36 .”
BackgroundA Survey of Sensors in Healthcare Workflow Monitoring
Antunes, R. S., Seewald, L. A., Rodrigues, V. F., Costa, C. A. D., Jr., L. G., Righi, R. R., Maier, A., Eskofier, B., Ollenschläger, M., Naderi, F., et al. (2019) · ACM Computing Surveys · doi:10.1145/3177852 · Cited by 48
Metadata
- Authors
- Shirehjini, A. A. N., Yassine, A., & Shirmohammadi, S.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2012-11
- Volume
- 16
- Issue
- 6
- Pages
- 1058-1069
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W2131194426
- Cited by
- 101
- References
- 0
- FWCI
- 5.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.