Measurement of MCG in Unshielded Environment Using a Second-Order SQUID Gradiometer
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
In this paper, we fabricated a low-TCsecond-order superconducting quantum interference device gradiometer (SQUID) to measure magnetocardiography (MCG) in unshielded environment. The second-order gradiometer consists of the pickup coil and the SQUID. The pickup coil is formed with two single-turn coils and one double-turn coil. The three coils are connected in order of single-, double-, and single-turn coil. The coupling polarity of two single coils is opposite to the double-turn coil. The SQUID is based on double relaxation oscillation SQUID (DROS), which consists of a hysteretic signal SQUID, a reference junction, and shunted a relaxation circuit with a resistor and an inductor. The DROS has ten times larger flux-to-voltage transfer coefficient (~ 1 mV/Phi0) than that of the conventional SQUID. Therefore, DROS could be operated with a simple flux-locked loop circuit. The pickup coil and the SQUID were fabricated on the independent wafers and connected superconductively using an Nb wire. The overall size of the second-order gradiometer is 94 times 12 mm2with a baseline of 35 mm. The average field noise was about 8 fT /radicHz at 100 Hz with the second-order gradiometer in shielded or unshielded environment. The noise level is low enough to measure MCG signals in the unshielded environment. Finally, we measure the MCG in shielded and unshielded environments by using the second-order gradiometer and compared the signal characteristics measured in both environments.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The second-order gradiometer, made up of two first-order gradiometers, can greatly reduce the magnetic field gradient noise from surroundings (45).”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [45]
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Wikswo, J. P. (1995) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/77.402511 · Cited by 201
Squid Gradiometers in Real Environments
Vrba, J. (1996) · Springer eBooks · doi:10.1007/978-94-011-5674-5_3 · Cited by 110
Adelerhof, D. J., Nijstad, H., Flokstra, J., & Rogalla, H. (1994) · Journal of Applied Physics · doi:10.1063/1.357392 · Cited by 56
Park, J.-W., & Jung, F. (2004) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2004.050 · Cited by 37
Lee, Y. H., Kwon, H.-C., Kim, J. M., Park, Y. K., & Park, J. C. (1997) · Applied Superconductivity · doi:10.1016/s0964-1807(98)00063-5 · Cited by 22
Self-citationComparison of Magnetocardiograms Measured Using Different SQUID Pickup Coil Configuration
Kang, C. S., Lee, Y. H., Kim, K., Yu, K. K., Kim, J. M., Kwon, H.-C., Kim, I. S., Park, Y. K., Lim, H. K., & Lee, S. G. (2007) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2007.898600 · Cited by 5
Self-citation
Research works printed but not linked: 1
- jaszezuk, 1991, Meas Sci Technol, 2
Cited by
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“The second-order gradiometer, made up of two first-order gradiometers, can greatly reduce the magnetic field gradient noise from surroundings ( 45 ).”
A Review of Magnetic Field Emissions From the Human Body: Sources, Sensors, and Uses
Zhu, K., & Kiourti, A. (2022) · IEEE Open Journal of Antennas and Propagation · doi:10.1109/ojap.2022.3186643 · Cited by 44
Multi-Channel Magnetocardiogardiography System Based on Low-Tc SQUIDs in an Unshielded Environment
Kong, X., Zhang, S., Wang, Y., Zeng, J., & Xie, X. (2012) · Physics Procedia · doi:10.1016/j.phpro.2012.06.161 · Cited by 27
“many researchers are trying to investigate the system can measure the MCG signal without an MSR (unshielded) or with a moderated shielded enclosure [5-8].”
BackgroundXi, H., Qian, X., Lu, M.-C., Mei, L., Rupprecht, S., Yang, Q., & Zhang, Q. (2016) · Scientific Reports · doi:10.1038/srep29740 · Cited by 27
Noninvasive magnetocardiography of a living rat based on a diamond quantum sensor
Yu, Z., Xie, Y., Jin, G., Zhu, Y., Zhang, Q., Shi, F., Wan, F.-Y., Luo, H., Tang, A., & Rong, X. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.064028 · Cited by 29
Swain, P. P., Sengottuvel, S., Patel, R., Mani, A., & Gireesan, K. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101664 · Cited by 21
Low Noise Active Shield for SQUID-Based Magnetocardiography Systems
Shanehsazzadeh, F., & Fardmanesh, M. (2017) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2017.2784683 · Cited by 21
Multi-channel MCG signals filtering method based on multivariate variational mode decomposition
Yang, K. Y., Xu, T., Pan, D., Zhang, Z., Wang, H., & Kong, X. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106806 · Cited by 13
Weakly Damped SQUID Gradiometer With Low Crosstalk for Magnetocardiography Measurement
Yang, K. Y., Chen, H., Kong, X., Lu, L., Li, M., Yang, R., & Xie, X. (2016) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2016.2615121 · Cited by 12
Chu, Z., Zhou, Y., Li, S. Z., Xu, Q., & Pan, L. (2025) · Applied Sciences · doi:10.3390/app15137599 · Cited by 11
Ohkubo, M. (2023) · Review of Scientific Instruments · doi:10.1063/5.0167372 · Cited by 9
Kaiss, A., Islam, M. A., & Kiourti, A. (2024) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2024.3426270 · Cited by 6
“Their operationis basedontheexpulsionof magnetic fields when cooled to very low temperatures (as close as absolute zero) [19], allowing superconducting materials to conduct electrical current for long periods while avoiding energy losses [20].”
Optimization of pick-up coils for weakly damped SQUID gradiometers
Yang, K. Y., Wang, J., Kong, X., Yang, R., & Chen, H. (2018) · Chinese Physics B · doi:10.1088/1674-1056/27/5/050701 · Cited by 6
Yang, K. Y., Zhao, A., Zhang, Y., Zhang, Q., Zhang, H., Wang, X., Rui, D., Huang, D., & Kong, X. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3384508 · Cited by 4
“For instance, Lee et al [13] developed a 64-channel system by second-order axial gradiometers in a moderate MSR for MCG imaging, and they even fabricated a kind of second-order planar gradiometer that could operate outside the MSR [13], [14].”
MethodAsymmetric Gradiometer System for Magnetocardiograms Measuring Without Magnetic Shielding
Wang, Q., Du, J., & Song, T. (2018) · IEEE International Magnetics Conference · doi:10.1109/intmag.2018.8508417 · Cited by 1
Innovative Analysis and Application on Magnetograms Signal
Wang, Y., & Zhou, L. (2022) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2174/1/012087
“This strategy of signal shielding using the control principle has a higher effect than passive signal shielding [5].”
BackgroundRecent advances in magnetocardiography
Kong, X., Yang, K., Zhang, Z., Pan, D., & Guo, C. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-41624-8.00001-2 · Cited by 2
Wavelet-based energy mapping analysis framework for magnetocardiography
Yang, K., Zhang, Z., Wang, H., Kong, X., Miao, P., & Chen, Z. (2026) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aeb67c
“Especially, the development of unshielded gradiometer [10, 11] technology represents a major breakthrough, as it substantially reduces the magnetic shielding costs associated with MCG.”
Metadata
- Authors
- Kang, C. S., Lee, Y. H., Yu, K. K., Kwon, H., Kim, J. M., Kim, K., Lim, H. K., Park, Y. K., & Lee, S. G.
- Affiliations
- Korea University (KR)
- Korea Research Institute of Standards and Science (KR)
- Venue
- IEEE Transactions on Magnetics
- Published
- 2009-06
- Volume
- 45
- Issue
- 6
- Pages
- 2882-2885
- ISSN
- 0018-9464 (ISSN-L)
- OpenAlex
- W2163265273
- Cited by
- 18
- References
- 8
- Citations by year
- 2025: 2 · 2024: 4 · 2023: 2 · 2022: 2 · 2021: 1 · 2019: 1 · 2018: 2 · 2017: 1 · 2016: 2 · 2012: 1
- FWCI
- 0.26
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Magnetics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Keywords
- magnetocardiography, unshielded environment, pickup coil, field noise, flux-locked loop
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.