Calibration of Room Temperature Magnetic Sensor Array for Biomagnetic Measurement
Open accessAbstract
Biomagnetic field measurement is a promising tool for the investigation of electrical activities in a living body. Room temperature (RT) magnetic sensors with an improved resolution such as magnetoresistance (MR) devices have been recently employed for the detection of weak magnetic fields, which were earlier detected solely using superconducting interference device magnetic sensors. The position, orientation, and sensitivity of each magnetic sensor in a sensor array must be precisely determined for accurate magnetic source analysis. We proposed a calibration method using an array of multiple coils, which is applicable to an RT magnetic sensor array. To demonstrate the validity of the proposed calibration method, we applied it to an MR device-based magnetocardiography (MCG) system equipped with an L-shaped planar sensor array, which was newly developed for the simultaneous observation of both anterior and lateral sides of the body. The deviation of the sensor parameters from the designed values was estimated via calibration. The result of the marker coil localization test indicated that the calibration considerably improved the accuracy of the magnetic source analysis. Finally, we demonstrated a preliminary MCG measurement using the calibrated magnetic sensor array.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists are queued
They are fetched later and appear here then.
References 8 · Cited by 39
Research works printed but not linked: 1
- 2018, Capable of Detecting Extremely Weak Biomagnetic Signals at Room Temperature
Metadata
- Authors
- Adachi, Y., Oyama, D., Terazono, Y., Hayashi, T., Shibuya, T., & Kawabata, S.
- Affiliations
- Kanazawa Institute of Technology (JP)
- TDK (Japan) (JP)
- Tokyo Medical and Dental University (JP)
- Venue
- IEEE Transactions on Magnetics
- Published
- 2019-07
- Volume
- 55
- Issue
- 7
- Pages
- 1-6
- ISSN
- 0018-9464 (ISSN-L)
- 1941-0069
- OpenAlex
- W2919377459
- Cited by
- 39
- References
- 8
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 3 · 2023: 8 · 2022: 6 · 2021: 5 · 2020: 2 · 2019: 2
- FWCI
- 1.35
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- IEEE Transactions on Magnetics (publishedVersion, cc-by)
- Funders
- Japan Society for the Promotion of Science (18K12044)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Earth and Planetary Sciences › Geophysics › Geomagnetism and Paleomagnetism Studies
- Keywords
- sensor array calibration, magnetocardiography, planar sensor array
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibration of Room Temperature Magnetic Sensor Array for Biomagnetic Measurement. https://app.cochat.ai/papers/10.1109/tmag.2019.2895355
- The paper
- Adachi, Y., Oyama, D., Terazono, Y., Hayashi, T., Shibuya, T., & Kawabata, S. (2019). Calibration of Room Temperature Magnetic Sensor Array for Biomagnetic Measurement. IEEE Transactions on Magnetics. https://doi.org/10.1109/tmag.2019.2895355
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.