Calibration of Room Temperature Magnetic Sensor Array for Biomagnetic Measurement

Open access

Abstract

Biomagnetic field measurement is a promising tool for the investigation of electrical activities in a living body. Room temperature (RT) magnetic sensors with an improved resolution such as magnetoresistance (MR) devices have been recently employed for the detection of weak magnetic fields, which were earlier detected solely using superconducting interference device magnetic sensors. The position, orientation, and sensitivity of each magnetic sensor in a sensor array must be precisely determined for accurate magnetic source analysis. We proposed a calibration method using an array of multiple coils, which is applicable to an RT magnetic sensor array. To demonstrate the validity of the proposed calibration method, we applied it to an MR device-based magnetocardiography (MCG) system equipped with an L-shaped planar sensor array, which was newly developed for the simultaneous observation of both anterior and lateral sides of the body. The deviation of the sensor parameters from the designed values was estimated via calibration. The result of the marker coil localization test indicated that the calibration considerably improved the accuracy of the magnetic source analysis. Finally, we demonstrated a preliminary MCG measurement using the calibrated magnetic sensor array.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmag.2019.2895355

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists are queued

They are fetched later and appear here then.

References 8 · Cited by 39

Research works printed but not linked: 1

  1. 2018, Capable of Detecting Extremely Weak Biomagnetic Signals at Room Temperature

Metadata

Authors
Adachi, Y., Oyama, D., Terazono, Y., Hayashi, T., Shibuya, T., & Kawabata, S.
Affiliations
  • Kanazawa Institute of Technology (JP)
  • TDK (Japan) (JP)
  • Tokyo Medical and Dental University (JP)
Venue
IEEE Transactions on Magnetics
Published
2019-07
Volume
55
Issue
7
Pages
1-6
ISSN
  • 0018-9464 (ISSN-L)
  • 1941-0069
OpenAlex
W2919377459
Cited by
39
References
8
Citations by year
2026: 5 · 2025: 8 · 2024: 3 · 2023: 8 · 2022: 6 · 2021: 5 · 2020: 2 · 2019: 2
FWCI
1.35
Type
journal article
Language
en
Open access
Locations
IEEE Transactions on Magnetics (publishedVersion, cc-by)
Funders
Japan Society for the Promotion of Science (18K12044)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
  • Physical Sciences › Earth and Planetary Sciences › Geophysics › Geomagnetism and Paleomagnetism Studies
Keywords
sensor array calibration, magnetocardiography, planar sensor array

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Calibration of Room Temperature Magnetic Sensor Array for Biomagnetic Measurement. https://app.cochat.ai/papers/10.1109/tmag.2019.2895355
The paper
Adachi, Y., Oyama, D., Terazono, Y., Hayashi, T., Shibuya, T., & Kawabata, S. (2019). Calibration of Room Temperature Magnetic Sensor Array for Biomagnetic Measurement. IEEE Transactions on Magnetics. https://doi.org/10.1109/tmag.2019.2895355

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.