The DOI matches its Crossref record.
The Rutgers Master II-new design force-feedback glove
Abstract
The Rutgers Master II-ND glove is a haptic interface designed for dextrous interactions with virtual environments. The glove provides force feedback up to 16 N each to the thumb, index, middle, and ring fingertips. It uses custom pneumatic actuators arranged in a direct-drive configuration in the palm. Unlike commercial haptic gloves, the direct-drive actuators make unnecessary cables and pulleys, resulting in a more compact and lighter structure. The force-feedback structure also serves as position measuring exoskeleton, by integrating noncontact Hall-effect and infrared sensors. The glove is connected to a haptic-control interface that reads its sensors and servos its actuators. The interface has pneumatic servovalves, signal conditioning electronics, A/D/A boards, power supply and an imbedded Pentium PC. This distributed computing assures much faster control bandwidth than would otherwise be possible. Communication with the host PC is done over an RS232 line. Comparative data with the CyberGrasp commercial haptic glove is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Virtual Environments for Motor Rehabilitation: Review
Holden, M. K. (2005) · CyberPsychology & Behavior · doi:10.1089/cpb.2005.8.187 · Cited by 1,154
Wearable Haptic Systems for the Fingertip and the Hand: Taxonomy, Review, and Perspectives
Pacchierotti, C., Sinclair, S., Solazzi, M., Frisoli, A., Hayward, V., & Prattichizzo, D. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2689006 · Cited by 825
Gu, X., Zhang, Y., Sun, W., Bian, Y., Zhou, D., & Kristensson, P. O. (2016) · Proceedings of the 2016 CHI Conference on Human Factors in Computing Systems · doi:10.1145/2858036.2858487 · Cited by 327
Wearable Soft Technologies for Haptic Sensing and Feedback
Yin, J., Hinchet, R., Shea, H., & Majidi, C. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202007428 · Cited by 325
Mediated social touch: a review of current research and future directions
Haans, A., & IJsselsteijn, W. (2006) · Virtual Reality · doi:10.1007/s10055-005-0014-2 · Cited by 303
Metadata
- Authors
- Bouzit, M., Burdea, G., Popescu, G., & Boian, R.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2002-06
- Volume
- 7
- Issue
- 2
- Pages
- 256-263
- ISSN
- 1083-4435 (ISSN-L)
- OpenAlex
- W2150606742
- Cited by
- 570
- References
- 0
- FWCI
- 31.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Rutgers Master II-new design force-feedback glove. https://app.cochat.ai/papers/10.1109/tmech.2002.1011262
- The paper
- Bouzit, M., Burdea, G., Popescu, G., & Boian, R. (2002). The Rutgers Master II-new design force-feedback glove. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2002.1011262
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.