The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement
Open accessAbstract
Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jemal, A., Siegel, R., Ward, E., Murray, T., Xu, J., & Thun, M. J. (2007) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.57.1.43 · Cited by 7,439 · cited 1×
“AC HY EAR approximately 1.5 M core needle biopsies are performed, yielding about 220 000 new prostate cancer cases [ 1 ].”
BackgroundInfluentialTsekos, N. V., Khanicheh, A., Christoforou, E., & Mavroidis, C. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.121806.160642 · Cited by 202
“MRI Stealth” robot for prostate interventions
Stoianovici, D., Song, D., Petrisor, D., Ursu, D., Mazilu, D., Mutener, M., Schar, M., & Patriciu, A. (2007) · Minimally Invasive Therapy & Allied Technologies · doi:10.1080/13645700701520735 · Cited by 200
MRI/fMRI-compatible robotic system with force feedback for interaction with human motion
Gassert, R., Moser, R., Burdet, E., & Bleuler, H. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871897 · Cited by 188
An MRI-Compatible Surgical Robot for Precise Radiological Interventions
Hempel, E., Fischer, H., Gumb, L., Höhn, T., Krause, H., Voges, U., Breitwieser, H., Gutmann, B., Durke, J., Bock, M., et al. (2003) · Computer Aided Surgery · doi:10.3109/10929080309146052 · Cited by 135
Terris, M. K., Wallen, E., & Stamey, T. A. (2010) · Urologia Internationalis · doi:10.1159/000283071 · Cited by 117
Baumann, S. B., Noll, D. C., Kondziolka, D. S., Schneider, W., Nichols, T. E., Mintun, M. A., Lewine, J. D., Yonas, H., Orrison, W. W., & Sclabassi, R. J. (1995) · Journal of Image Guided Surgery · doi:10.1002/(sici)1522-712x(1995)1:4<242::aid-igs7>3.0.co;2-a · Cited by 56
Cited by
Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions
Park, Y.-L., Elayaperumal, S., Daniel, B., Ryu, S. C., Shin, M., Savall, J., Black, R. J., Moslehi, B., & Cutkosky, M. R. (2010) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2010.2080360 · Cited by 266
Metadata
- Authors
- Fischer, G. S., Iordachita, I., Csoma, C., Tokuda, J., DiMaio, S. P., Tempany, C. M., Hata, N., & Fichtinger, G.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2008-06
- Volume
- 13
- Issue
- 3
- Pages
- 295-305
- ISSN
- 1083-4435 (ISSN-L)
- OpenAlex
- W2155672172
- Cited by
- 292
- References
- 7
- FWCI
- 13.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement. https://app.cochat.ai/papers/10.1109/tmech.2008.924044
- The paper
- Fischer, G. S., Iordachita, I., Csoma, C., Tokuda, J., DiMaio, S. P., Tempany, C. M., Hata, N., & Fichtinger, G. (2008). MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2008.924044
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.