The DOI matches its Crossref record.
Three-Dimensional Needle Shape Reconstruction Using an Array of Fiber Bragg Grating Sensors
Abstract
We present a prototype of a flexible nitinol needle (φ 1.0 mm and length 172 mm) integrated with an array of 12 Fiber Bragg Grating (FBG) sensors. These sensors measure the axial strain, which enables the computation of the needle curvature. We reconstruct the three-dimensional (3-D) needle shape from the curvature. Experiments are performed where the needle is deflected in free space. The maximum errors between the experiments and beam theory-based model are 0.20 mm (in-plane deflection with single bend), 0.51 mm (in-plane deflection with double bend), and 1.66 mm (out-of-plane). We also describe kinematics-based and mechanics-based models for predicting the 3-D needle shape during insertion into soft tissue. We perform experiments where the needle is inserted into a soft-tissue simulant, and the 3-D needle shape is reconstructed using the FBG sensors. We compare the reconstructed needle shape to deflection obtained from camera images and our models. The maximum error between the experiments and the camera images is 0.74 mm. The maximum errors between the kinematics-based and mechanics-based models and the camera images are 3.77 mm and 2.20 mm, respectively. This study demonstrates that deflection models and needles integrated with FBG sensors have the potential to be used in combination with clinical imaging modalities in order to enable accurate needle steering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fiber Bragg grating sensors for monitoring of physical parameters: a comprehensive review
Sahota, J. K., Gupta, N., & Dhawan, D. (2020) · Optical Engineering · doi:10.1117/1.oe.59.6.060901 · Cited by 522
Shape Sensing Techniques for Continuum Robots in Minimally Invasive Surgery: A Survey
Shi, C., Luo, X., Qi, P., Li, T., Song, S., Najdovski, Z., Fukuda, T., & Ren, H. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2622361 · Cited by 420
Alambeigi, F., Aghajani Pedram, S., Speyer, J. L., Rosen, J., Iordachita, I., Taylor, R. H., & Armand, M. (2020) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2946726 · Cited by 48
Metadata
- Authors
- Roesthuis, R. J., Kemp, M., van den Dobbelsteen, J. J., & Misra, S.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2014-08
- Volume
- 19
- Issue
- 4
- Pages
- 1115-1126
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2147404381
- Cited by
- 281
- References
- 0
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-Dimensional Needle Shape Reconstruction Using an Array of Fiber Bragg Grating Sensors. https://app.cochat.ai/papers/10.1109/tmech.2013.2269836
- The paper
- Roesthuis, R. J., Kemp, M., van den Dobbelsteen, J. J., & Misra, S. (2014). Three-Dimensional Needle Shape Reconstruction Using an Array of Fiber Bragg Grating Sensors. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2013.2269836
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.