Stance-Phase Detection for ZUPT-Aided Foot-Mounted Pedestrian Navigation System
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Zero velocity updates (ZUPT) is an effective way for the foot-mounted inertial pedestrian navigation systems. For the ZUPT technique to work properly, it is necessary to correctly detect the stance phase of each gait cycle. An adaptive stance-phase detection method is proposed based solely on an inertial sensor, which deals with the measurement fluctuations in swing and stance phases differently, and applies a clustering algorithm to partition the potential gait phases into true and false clusters, thereby yielding a time threshold to eliminate the false gait phases. The roles of the detection parameters and the relationship between them are analyzed to offer some suggestions for parameter tuning. Detection performance is evaluated with multisubject experimental data collected at varying walking speeds. The evaluation results show that the proposed detection method performs well in the presence of measurement fluctuations, which can make the detection of stance phases more robust and the choice of detection parameters more flexible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zero-Velocity Detection—An Algorithm Evaluation
Skog, I., Handel, P., Nilsson, J. O., & Rantakokko, J. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2060723 · Cited by 662 · cited 1×
“Different detection methods have been compared in [22], and the results suggest that angular velocity is more reliable than acceleration for typical walking, which is supported by [11], [12] and our study.”
ResultJimenez, A. R., Seco, F., Prieto, J. C., & Guevara, J. (2010) · 2010 7th Workshop on Positioning, Navigation and Communication · doi:10.1109/wpnc.2010.5649300 · Cited by 469 · cited 6×
“Therefore, the correct stance-phase detection is crucial for the ZUPT-aided IPNS, which makes the estimated trajectories closer to the ground truth and smoother without abrupt discontinuities.”
BackgroundMethodInfluentialFoot mounted inertial system for pedestrian navigation
Godha, S., & Lachapelle, G. (2008) · Measurement Science and Technology · doi:10.1088/0957-0233/19/7/075202 · Cited by 230 · cited 3×
“The angular velocity was used alone in the form of magnitude [10], root mean square [16], and moving average [17]; the acceleration was used alone in the form of magnitude [18], moving average [19], and moving variance [20]; both measurements were used in [9] and [21].”
BackgroundMethodPedestrian tracking using inertial sensors
Feliz Alonso, R., Zalama Casanova, E., & Gómez García-Bermejo, J. (2009) · Journal of Physical Agents (JoPha) · doi:10.14198/jopha.2009.3.1.05 · Cited by 228 · cited 3×
“implemented the ZUPT by applying a velocity bias error to recalculate the velocity during both swing and stance phases [11].”
BackgroundMethodResultNon-GPS navigation for security personnel and first responders
Ojeda, L., & Borenstein, J. (2007) · Journal of Navigation · doi:10.1017/s0373463307004286 · Cited by 226 · cited 2×
“The INS-derived velocity was directly reset to zero during the stance phase in [7] and [8].”
BackgroundEvaluation of zero-velocity detectors for foot-mounted inertial navigation systems
Skog, I., Nilsson, J.-O., & Handel, P. (2010) · 2010 International Conference on Indoor Positioning and Indoor Navigation · doi:10.1109/ipin.2010.5646936 · Cited by 213 · cited 3×
“Extra sensors in addition to the IMU have been used to aid the stance-phase detection, such as radio frequency sensors, cameras, and pressure sensors [8], [13], [14].”
BackgroundMethodSelf-contained Position Tracking of Human Movement Using Small Inertial/Magnetic Sensor Modules
Yun, X., Bachmann, E. R., Moore, H., & Calusdian, J. (2007) · Proceedings 2007 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2007.363845 · Cited by 192 · cited 1×
“3% in outdoor environment were reported in [30].”
BackgroundMannini, A., & Sabatini, A. M. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.06.017 · Cited by 179 · cited 1×
“The first way divides a gait cycle into four phases, and the stance phase lasts from FF to HO corresponding to about 30% of the gait cycle [25].”
BackgroundYun, X., Calusdian, J., Bachmann, E. R., & McGhee, R. B. (2012) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2011.2179830 · Cited by 169 · cited 4×
“applied an acceleration bias error to correct the acceleration during the swing phase [12].”
BackgroundMethodResultInfluentialPersonal Navigation via High-Resolution Gait-Corrected Inertial Measurement Units
Bebek, Ö., Suster, M. A., Rajgopal, S., Fu, M. J., Huang, X., Cavusoglu, M. C., Young, D. J., Mehregany, M., van den Bogert, A. J., & Mastrangelo, C. H. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2046595 · Cited by 160 · cited 3×
“Extra sensors in addition to the IMU have been used to aid the stance-phase detection, such as radio frequency sensors, cameras, and pressure sensors [8], [13], [14].”
BackgroundMethod
Cited by
Wearables and the Internet of Things (IoT), Applications, Opportunities, and Challenges: A Survey
John Dian, F., Vahidnia, R., & Rahmati, A. (2020) · IEEE Access · doi:10.1109/access.2020.2986329 · Cited by 386
Mencarini, E., Rapp, A., Tirabeni, L., & Zancanaro, M. (2019) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2019.2919702 · Cited by 169
“[3] and human activity recognition using wearable sensors [4]– [6], which allowed for the collection of accurate information”
IMU-Based Monitoring for Assistive Diagnosis and Management of IoHT: A Review
Bo, F., Yerebakan, M., Dai, Y., Wang, W., Li, J., Hu, B., & Gao, S. (2022) · Healthcare · doi:10.3390/healthcare10071210 · Cited by 35
“To obtain the desired accuracy level, the following methods are normally utilized, including bias compensation, distortion rejection, alignment, filtering (e.g., complementary filter (CF) [33] and Kalman filter (KF) [34]), and zero-velocity update (ZUPT) [35].”
Metadata
- Authors
- Wang, Z., Zhao, H., Qiu, S., & Gao, Q.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2015-12
- Volume
- 20
- Issue
- 6
- Pages
- 3170-3181
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W1896503986
- Cited by
- 196
- References
- 27
- FWCI
- 21.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.