The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Multiscale contrast enhancement for radiographies: Laplacian pyramid versus fast wavelet transform
Abstract
Contrast enhancement of radiographies based on a multiscale decomposition of the images recently has proven to be a far more versatile and efficient method than regular unsharp-masking techniques, while containing these as a subset. In this paper, we compare the performance of two multiscale-methods, namely the Laplacian Pyramid and the fast wavelet transform (FWT). We find that enhancement based on the FWT suffers from one serious drawback-the introduction of visible artifacts when large structures are enhanced strongly. By contrast, the Laplacian Pyramid allows a smooth enhancement of large structures, such that visible artifacts can be avoided. Only for the enhancement of very small details, for denoising applications or compression of images, the FWT may have some advantages over the Laplacian Pyramid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
The Laplacian pyramid as a compact image code
Burt, P., & Adelson, E. (1983) · IEEE Transactions on Communications · doi:10.1109/tcom.1983.1095851 · Cited by 6,077
Cited by
Naturalness Preserved Enhancement Algorithm for Non-Uniform Illumination Images
Wang, S., Zheng, J., Hu, H.-M., & Li, B. (2013) · IEEE Transactions on Image Processing · doi:10.1109/tip.2013.2261309 · Cited by 1,755
Computer-aided detection and classification of microcalcifications in mammograms: a survey
Cheng, H. D., Cai, X., Chen, X., Hu, L., & Lou, X. (2003) · Pattern Recognition · doi:10.1016/s0031-3203(03)00192-4 · Cited by 563
Pu, Y.-F., Zhou, J.-L., & Yuan, X. (2010) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2035980 · Cited by 466
Local Laplacian filters: edge-aware image processing with a Laplacian pyramid
Paris, S., Hasinoff, S. W., & Kautz, J. (2011) · ACM Transactions on Graphics · doi:10.1145/2010324.1964963 · Cited by 384
Local Laplacian filters: edge-aware image processing with a Laplacian pyramid
Paris, S., Hasinoff, S. W., & Kautz, J. (2011) · ACM SIGGRAPH 2011 papers · doi:10.1145/1964921.1964963 · Cited by 322
Metadata
- Authors
- Dippel, S., Stahl, M., Wiemker, R., & Blaffert, T.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2002-04
- Volume
- 21
- Issue
- 4
- Pages
- 343-353
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2157233332
- Cited by
- 200
- References
- 2
- FWCI
- 5.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiscale contrast enhancement for radiographies: Laplacian pyramid versus fast wavelet transform. https://app.cochat.ai/papers/10.1109/tmi.2002.1000258
- The paper
- Dippel, S., Stahl, M., Wiemker, R., & Blaffert, T. (2002). Multiscale contrast enhancement for radiographies: Laplacian pyramid versus fast wavelet transform. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2002.1000258
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.