The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An eulerian pde approach for computing tissue thickness
Open accessAbstract
We outline an Eulerian framework for computing the thickness of tissues between two simply connected boundaries that does not require landmark points or parameterizations of either boundary. Thickness is defined as the length of correspondence trajectories, which run from one tissue boundary to the other, and which follow a smooth vector field constructed in the region between the boundaries. A pair of partial differential equations (PDEs) that are guided by this vector field are then solved over this region, and the sum of their solutions yields the thickness of the tissue region. Unlike other approaches, this approach does not require explicit construction of any correspondence trajectories. An efficient, stable, and computationally fast solution to these PDEs is found by careful selection of finite differences according to an upwinding condition. The behavior and performance of our method is demonstrated on two simulations and two magnetic resonance imaging data sets in two and three dimensions. These experiments reveal very good performance and show strong potential for application in tissue thickness visualization and quantification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Snakes, shapes, and gradient vector flow
Xu, C., & Prince, J. L. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661186 · Cited by 4,001
Self-citation
Cited by
Han, X., Jovicich, J., Salat, D., van der Kouwe, A., Quinn, B., Czanner, S., Busa, E., Pacheco, J., Albert, M., Killiany, R., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.051 · Cited by 1,508
Cortical thickness analysis examined through power analysis and a population simulation
Lerch, J. P., & Evans, A. C. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.045 · Cited by 710
Large-scale evaluation of ANTs and FreeSurfer cortical thickness measurements
Tustison, N. J., Cook, P. A., Klein, A., Song, G., Das, S. R., Duda, J. T., Kandel, B. M., van Strien, N., Stone, J. R., Gee, J. C., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.05.044 · Cited by 670
Dickerson, B. C., Fenstermacher, E., Salat, D. H., Wolk, D. A., Maguire, R. P., Desikan, R., Pacheco, J., Quinn, B. T., Van der Kouwe, A., Greve, D. N., et al. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.08.042 · Cited by 290
Lee, J. K., Lee, J.-M., Kim, J. S., Kim, I. Y., Evans, A. C., & Kim, S. I. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.044 · Cited by 108
Metadata
- Authors
- Yezzi, A. J., & Prince, J. L.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2003-10
- Volume
- 22
- Issue
- 10
- Pages
- 1332-1339
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2157273833
- Cited by
- 183
- References
- 1
- FWCI
- 7.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An eulerian pde approach for computing tissue thickness. https://app.cochat.ai/papers/10.1109/tmi.2003.817775
- The paper
- Yezzi, A. J., & Prince, J. L. (2003). An eulerian pde approach for computing tissue thickness. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2003.817775
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.