The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Automatic Identification of the Pectoral Muscle in Mammograms
Abstract
The pectoral muscle represents a predominant density region in most medio-lateral oblique (MLO) views of mammograms; its inclusion can affect the results of intensity-based image processing methods or bias procedures in the detection of breast cancer. Local analysis of the pectoral muscle may be used to identify the presence of abnormal axillary lymph nodes, which may be the only manifestation of occult breast carcinoma. We propose a new method for the identification of the pectoral muscle in MLO mammograms based upon a multiresolution technique using Gabor wavelets. This new method overcomes the limitation of the straight-line representation considered in our initial investigation using the Hough transform. The method starts by convolving a group of Gabor filters, specially designed for enhancing the pectoral muscle edge, with the region of interest containing the pectoral muscle. After computing the magnitude and phase images using a vector-summation procedure, the magnitude value of each pixel is propagated in the direction of the phase. The resulting image is then used to detect the relevant edges. Finally, a post-processing stage is used to find the true pectoral muscle edge. The method was applied to 84 MLO mammograms from the Mini-MIAS (Mammographic Image Analysis Society, London, U.K.) database. Evaluation of the pectoral muscle edge detected in the mammograms was performed based upon the percentage of false-positive (FP) and false-negative (FN) pixels determined by comparison between the numbers of pixels enclosed in the regions delimited by the edges identified by a radiologist and by the proposed method. The average FP and FN rates were, respectively, 0.58% and 5.77%. Furthermore, the results of the Gabor-filter-based method indicated low Hausdorff distances with respect to the hand-drawn pectoral muscle edges, with the mean and standard deviation being 3.84 +/- 1.73 mm over 84 images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daugman, J. G. (1985) · Journal of the Optical Society of America A · doi:10.1364/josaa.2.001160 · Cited by 3,219
Jones, J. P., & Palmer, L. A. (1987) · Journal of Neurophysiology · doi:10.1152/jn.1987.58.6.1233 · Cited by 1,658 · cited 1×
“5 octaves, and their angular bandwidth is expected to be smaller than 30 [13], [14].”
Background
Cited by
Computer-Aided Detection and Diagnosis of Breast Cancer With Mammography: Recent Advances
Tang, J., Rangayyan, R. M., Xu, J., El Naqa, I., & Yang, Y. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2009441 · Cited by 619
Self-citationA review of computer-aided diagnosis of breast cancer: Toward the detection of subtle signs
Rangayyan, R. M., Ayres, F. J., & Leo Desautels, J. E. (2007) · Journal of the Franklin Institute · doi:10.1016/j.jfranklin.2006.09.003 · Cited by 337
Self-citation
Metadata
- Authors
- Ferrari, R. J., Rangayyan, R. M., Desautels, J. E. L., Borges, R. A., & Frere, A. F.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2004-02
- Volume
- 23
- Issue
- 2
- Pages
- 232-245
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2102427741
- Cited by
- 213
- References
- 2
- FWCI
- 8.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.