Abstract

Changes in vessel wall elasticity may be indicative of vessel pathologies. It is known, for example, that the presence of plaque stiffens the vascular wall, and that the heterogeneity of its composition may lead to plaque rupture and thrombosis. Another domain of application where ultrasound elastography may be of interest is the study of vascular wall elasticity to predict the risk of aneurysmal tissue rupture. In this paper, this technology is introduced as an approach to noninvasively characterize superficial arteries. In such a case, a linear array ultrasound transducer is applied on the skin over the region of interest, and the arterial tissue is dilated by the normal cardiac pulsation. The elastograms, the equivalent elasticity images, are computed from the assessment of the vascular tissue motion. Investigating the forward problem, it is shown that motion parameters might be difficult to interpret; that is because tissue motion occurs radially within the vessel wall while the ultrasound beam propagates axially. As a consequence of that, the elastograms are subjected to hardening and softening artefacts, which are to be counteracted. In this paper, the Von Mises (VM) coefficient is proposed as a new parameter to circumvent such mechanical artefacts and to appropriately characterize the vessel wall. Regarding the motion assessment, the Lagrangian estimator was used; that is because it provides the full two-dimensional strain tensor necessary to compute the VM coefficient. The theoretical model was validated with biomechanical simulations of the vascular wall properties. The results allow believing in the potential of the method to differentiate hard plaques and lipid pools from normal vascular tissue. Potential in vivo implementation of noninvasive vascular elastography to characterize abdominal aneurysms and superficial arteries such as the femoral and the carotid is discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2003.823066

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 158

Metadata

Authors
Maurice, R. L., Ohayon, J., Fretigny, Y., Bertrand, M., Soulez, G., & Cloutier, G.
Venue
IEEE Transactions on Medical Imaging
Published
2004-02
Volume
23
Issue
2
Pages
164-180
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2096578443
Cited by
158
References
0
FWCI
6.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Vascular Elastography: Theoretical Framework. https://app.cochat.ai/papers/10.1109/tmi.2003.823066
The paper
Maurice, R. L., Ohayon, J., Fretigny, Y., Bertrand, M., Soulez, G., & Cloutier, G. (2004). Noninvasive Vascular Elastography: Theoretical Framework. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2003.823066

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.