Parametric Shape Modeling Using Deformable Superellipses for Prostate Segmentation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Automatic prostate segmentation in ultrasound images is a challenging task due to speckle noise, missing boundary segments, and complex prostate anatomy. One popular approach has been the use of deformable models. For such techniques, prior knowledge of the prostate shape plays an important role in automating model initialization and constraining model evolution. In this paper, we have modeled the prostate shape using deformable superellipses. This model was fitted to 594 manual prostate contours outlined by five experts. We found that the superellipse with simple parametric deformations can efficiently model the prostate shape with the Hausdorff distance error (model versus manual outline) of 1.32 +/- 0.62 mm and mean absolute distance error of 0.54 +/- 0.20 mm. The variability between the manual outlinings and their corresponding fitted deformable superellipses was significantly less than the variability between human experts with p-value being less than 0.0001. Based on this deformable superellipse model, we have developed an efficient and robust Bayesian segmentation algorithm. This algorithm was applied to 125 prostate ultrasound images collected from 16 patients. The mean error between the computer-generated boundaries and the manual outlinings was 1.36 +/- 0.58 mm, which is significantly less than the manual interobserver distances. The algorithm was also shown to be fairly insensitive to the choice of the initial curve.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Active Shape Models-Their Training and Application
Cootes, T. F., Taylor, C. J., Cooper, D. H., & Graham, J. (1995) · Computer Vision and Image Understanding · doi:10.1006/cviu.1995.1004 · Cited by 7,190 · cited 1×
“These anatomical points must be capable of being unambiguously and consistently located in different specimens [13].”
Background
Cited by
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
“In order to restrict user interaction, a deformable superellipse was employed as a parametric shape model for the prostate in a later work [88].”
BackgroundMethodInfluentialDeep Attentive Features for Prostate Segmentation in 3D Transrectal Ultrasound
Wang, Y., Ni, D., Dou, H., Hu, X., Zhu, L., Yang, X., Xu, M., Qin, J., Heng, P.-A., & Wang, T. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2913184 · Cited by 175
Ultrasound image segmentation and tissue characterization
Noble, J. A. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim604 · Cited by 159
Xu, L., Liu, M., Shen, Z., Wang, H., Liu, X., Wang, X., Wang, S., Li, T., Yu, S., Hou, M., et al. (2020) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2019.101690 · Cited by 87
Metadata
- Authors
- Gong, L., Pathak, S. D., Haynor, D. R., Cho, P. S., & Kim, Y.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2004-03
- Volume
- 23
- Issue
- 3
- Pages
- 340-349
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2126763729
- Cited by
- 158
- References
- 1
- FWCI
- 11.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.