The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Surface Normal Overlap: A Computer-Aided Detection Algorithm With Application to Colonic Polyps and Lung Nodules in Helical CT
Abstract
We developed a novel computer-aided detection (CAD) algorithm called the surface normal overlap method that we applied to colonic polyp detection and lung nodule detection in helical computed tomography (CT) images. We demonstrate some of the theoretical aspects of this algorithm using a statistical shape model. The algorithm was then optimized on simulated CT data and evaluated using a per-lesion cross-validation on 8 CT colonography datasets and on 8 chest CT datasets. It is able to achieve 100% sensitivity for colonic polyps 10 mm and larger at 7.0 false positives (FPs)/dataset and 90% sensitivity for solid lung nodules 6 mm and larger at 5.6 FP/dataset.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
A Study of Cross-Validation and Bootstrap for Accuracy Estimation and Model Selection
Kohavi, R. (1995) · Zenodo · doi:10.5281/zenodo.19712698 · Cited by 10,909
Cited by
Machine learning and radiology
Wang, S., & Summers, R. M. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.02.005 · Cited by 697
Computer analysis of computed tomography scans of the lung: a survey
Sluimer, I., Schilham, A., Prokop, M., & van Ginneken, B. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.862753 · Cited by 556
Murphy, K., van Ginneken, B., Schilham, A. M. R., de Hoop, B. J., Gietema, H. A., & Prokop, M. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.07.001 · Cited by 331
van Ginneken, B., Armato, S. G., de Hoop, B., van Amelsvoort-van de Vorst, S., Duindam, T., Niemeijer, M., Murphy, K., Schilham, A., Retico, A., Fantacci, M. E., et al. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.05.005 · Cited by 298
Shape-Based Computer-Aided Detection of Lung Nodules in Thoracic CT Images
Ye, X., Lin, X., Dehmeshki, J., Slabaugh, G., & Beddoe, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2017027 · Cited by 297
Metadata
- Authors
- Paik, D. S., Beaulieu, C. F., Rubin, G. D., Acar, B., Jeffrey, R. B., Yee, J., Dey, J., & Napel, S.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2004-06
- Volume
- 23
- Issue
- 6
- Pages
- 661-675
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2157469204
- Cited by
- 248
- References
- 2
- FWCI
- 17.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surface Normal Overlap: A Computer-Aided Detection Algorithm With Application to Colonic Polyps and Lung Nodules in Helical CT. https://app.cochat.ai/papers/10.1109/tmi.2004.826362
- The paper
- Paik, D. S., Beaulieu, C. F., Rubin, G. D., Acar, B., Jeffrey, R. B., Yee, J., Dey, J., & Napel, S. (2004). Surface Normal Overlap: A Computer-Aided Detection Algorithm With Application to Colonic Polyps and Lung Nodules in Helical CT. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2004.826362
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).