Robust quantification of in vitro angiogenesis through image analysis
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
An automated image analysis method for quantification of in vitro angiogenesis is presented. The method is designed for in vitro angiogenesis assays that are based on co-culturing endothelial cells with fibroblasts. Such assays are used in many current studies in which anti-angiogenic agents for the treatment of cancer are being sought. This search requires accurate quantification of the stimulatory and inhibitory effects of the different agents. The quantification method gives lengths and sizes of the tubule complexes as well as the numbers of junctions in each of them. The method is tested with a set of test images obtained with a commercially available in vitro angiogenesis assay. The results correctly indicate the inhibitory effect of suramin and the stimulatory effect of vascular endothelial growth factor. Moreover, the image analysis method is shown to be robust against variations in illumination. We have implemented a software package that utilizes the methods. The software as well as a set of test images are available at http://www.cs.tut.fi/sgn/csb/angioquant/.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,398 · cited 3×
“2(a), Otsu's algorithm gives TH = 146, and the resulting binary image is shown superimposed in red color on the original image in Fig.”
MethodInfluentialA Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004 · cited 2×
“In this case, the same result could have been obtained by applying hysteresis thresholding as suggested by Canny [7], i.”
MethodDavies, A., & Fennessy, P. (2001) · Digital Imaging for Photographers · doi:10.1016/b978-0-240-51590-8.50007-x · Cited by 4,371
Role of angiogenesis in tumor growth and metastasis
Folkman, J. (2002) · Seminars in Oncology · doi:10.1053/sonc.2002.37263 · Cited by 2,404
Role of angiogenesis in tumor growth and metastasis
FOLKMAN, J. (2002) · Seminars in Oncology · doi:10.1016/s0093-7754(02)70065-1 · Cited by 2,400 · cited 1×
“It can occur abnormally around malignant tumors, and anti-angiogenic agents for the treatment of cancer are currently being sought [1], [2].”
BackgroundThinning methodologies-a comprehensive survey
Lam, L., Lee, S.-W., & Suen, C. Y. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.161346 · Cited by 1,785 · cited 1×
“A comprehensive review of thinning methods can be found in [10].”
BackgroundClinical translation of angiogenesis inhibitors
Kerbel, R., & Folkman, J. (2002) · Nature Reviews Cancer · doi:10.1038/nrc905 · Cited by 1,517 · cited 1×
“It can occur abnormally around malignant tumors, and anti-angiogenic agents for the treatment of cancer are currently being sought [1], [2].”
BackgroundParallel thinning with two-subiteration algorithms
Guo, Z., & Hall, R. W. (1989) · Communications of the ACM · doi:10.1145/62065.62074 · Cited by 451 · cited 1×
“A thinning algorithm suggested by Guo and Hall [13] is suitable for our application.”
MethodQuantitative angiogenesis assays: Progress and problems
Jain, R. K., Schlenger, K., Hockel, M., & Yuan, F. (1997) · Nature Medicine · doi:10.1038/nm1197-1203 · Cited by 385 · cited 1×
“Numerous in vivo angiogenesis assays have been developed [3].”
BackgroundComparison of three in vitro human ‘angiogenesis’ assays with capillaries formed in vivo
Donovan, D., Brown, N. J., Bishop, E. T., & Lewis, C. E. (2001) · Angiogenesis · doi:10.1023/a:1012218401036 · Cited by 342
Cited by
van Balkom, B. W. M., de Jong, O. G., Smits, M., Brummelman, J., den Ouden, K., de Bree, P. M., van Eijndhoven, M. A. J., Pegtel, D. M., Stoorvogel, W., Würdinger, T., et al. (2013) · Blood · doi:10.1182/blood-2013-02-478925 · Cited by 515
Kottakis, F., Polytarchou, C., Foltopoulou, P., Sanidas, I., Kampranis, S. C., & Tsichlis, P. N. (2011) · Molecular Cell · doi:10.1016/j.molcel.2011.06.020 · Cited by 224
“The total length of capillary tubes in the total area of each well was measured with the Angioquant image analysis software (Niemistö et al., 2005).”
Poldervaart, M. T., Gremmels, H., van Deventer, K., Fledderus, J. O., Öner, F. C., Verhaar, M. C., Dhert, W. J. A., & Alblas, J. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.04.007 · Cited by 224
Graphene Oxides Show Angiogenic Properties
Mukherjee, S., Sriram, P., Barui, A. K., Nethi, S. K., Veeriah, V., Chatterjee, S., Suresh, K. I., & Patra, C. R. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500155 · Cited by 220
van Koppen, A., Joles, J. A., van Balkom, B. W. M., Lim, S. K., de Kleijn, D., Giles, R. H., & Verhaar, M. C. (2012) · PLoS ONE · doi:10.1371/journal.pone.0038746 · Cited by 204
Zinc oxide nanoflowers make new blood vessels
Barui, A. K., Veeriah, V., Mukherjee, S., Manna, J., Patel, A. K., Patra, S., Pal, K., Murali, S., Rana, R. K., Chatterjee, S., et al. (2012) · Nanoscale · doi:10.1039/c2nr32369a · Cited by 172
“Images were analysed using Angioquant software (Niemistö et al., 2005).”
Method
Metadata
- Authors
- Niemisto, A., Dunmire, V., Yli-Harja, O., Zhang, W., & Shmulevich, I.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2005-04
- Volume
- 24
- Issue
- 4
- Pages
- 549-553
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2162147695
- Cited by
- 197
- References
- 12
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.