Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 254

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.

Direct reconstruction of kinetic parameter images from dynamic PET data

Kamasak, M.E., Bouman, C.A., Morris, E.D., Sauer, K.·2005·IEEE Transactions on Medical Imaging

Abstract

Our goal in this paper is the estimation of kinetic model parameters for each voxel corresponding to a dense three-dimensional (3-D) positron emission tomography (PET) image. Typically, the activity images are first reconstructed from PET sinogram frames at each measurement time, and then the kinetic parameters are estimated by fitting a model to the reconstructed time-activity response of each voxel. However, this "indirect" approach to kinetic parameter estimation tends to reduce signal-to-noise ratio (SNR) because of the requirement that the sinogram data be divided into individual time frames. In 1985, Carson and Lange proposed, but did not implement, a method based on the expectation-maximization (EM) algorithm for direct parametric reconstruction. The approach is "direct" because it estimates the optimal kinetic parameters directly from the sinogram data, without an intermediate reconstruction step. However, direct voxel-wise parametric reconstruction remained a challenge due to the unsolved complexities of inversion and spatial regularization. In this paper, we demonstrate and evaluate a new and efficient method for direct voxel-wise reconstruction of kinetic parameter images using all frames of the PET data. The direct parametric image reconstruction is formulated in a Bayesian framework, and uses the parametric iterative coordinate descent (PICD) algorithm to solve the resulting optimization problem. The PICD algorithm is computationally efficient and is implemented with spatial regularization in the domain of the physiologically relevant parameters. Our experimental simulations of a rat head imaged in a working small animal scanner indicate that direct parametric reconstruction can substantially reduce root-mean-squared error (RMSE) in the estimation of kinetic parameters, as compared to indirect methods, without appreciably increasing computation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2005.845317

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 44 references

Cited by

See all 254

Metadata

Authors
Kamasak, M. E., Bouman, C. A., Morris, E. D., & Sauer, K.
Venue
IEEE Transactions on Medical Imaging
Published
2005-05
Volume
24
Issue
5
Pages
636-650
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2101301278
Cited by
254
References
44
FWCI
12.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Direct reconstruction of kinetic parameter images from dynamic PET data. https://app.cochat.ai/papers/10.1109/tmi.2005.845317
The paper
Kamasak, M. E., Bouman, C. A., Morris, E. D., & Sauer, K. (2005). Direct reconstruction of kinetic parameter images from dynamic PET data. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2005.845317

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.