CoChat

Lung motion correction on respiratory gated 3-D PET/CT images

Dawood, M., Lang, N., Xiaoyi Jiang, Schafers, K.P. · 2006 · IEEE Transactions on Medical Imaging
Cited by 184

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Motion is a source of degradation in positron emission tomography (PET)/computed tomography (CT) images. As the PET images represent the sum of information over the whole respiratory cycle, attenuation correction with the help of CT images may lead to false staging or quantification of the radioactive uptake especially in the case of small tumors. We present an approach avoiding these difficulties by respiratory-gating the PET data and correcting it for motion with optical flow algorithms. The resulting dataset contains all the PET information and minimal motion and, thus, allows more accurate attenuation correction and quantification.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2006.870892

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 184

Metadata

Authors
Dawood, M., Lang, N., Jiang, X., & Schafers, K. P.
Venue
IEEE Transactions on Medical Imaging
Published
2006-04
Volume
25
Issue
4
Pages
476-485
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2104121925
Cited by
184
References
3
FWCI
11.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.