Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 288

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Morphological segmentation and partial volume analysis for volumetry of solid pulmonary lesions in thoracic CT scans

Kuhnigk, J.-M., Dicken, V., Bornemann, L., Bakai, A., Wormanns, D., Krass, S., Peitgen, H.-O.·2006·IEEE Transactions on Medical Imaging

Abstract

Volumetric growth assessment of pulmonary lesions is crucial to both lung cancer screening and oncological therapy monitoring. While several methods for small pulmonary nodules have previously been presented, the segmentation of larger tumors that appear frequently in oncological patients and are more likely to be complexly interconnected with lung morphology has not yet received much attention. We present a fast, automated segmentation method that is based on morphological processing and is suitable for both small and large lesions. In addition, the proposed approach addresses clinical challenges to volume assessment such as variations in imaging protocol or inspiration state by introducing a method of segmentation-based partial volume analysis (SPVA) that follows on the segmentation procedure. Accuracy and reproducibility studies were performed to evaluate the new algorithms. In vivo interobserver and interscan studies on low-dose data from eight clinical metastasis patients revealed that clinically significant volume change can be detected reliably and with negligible computation time by the presented methods. In addition, phantom studies were conducted. Based on the segmentation performed with the proposed method, the performance of the SPVA volumetry method was compared with the conventional technique on a phantom that was scanned with different dosages and reconstructed with varying parameters. Both systematic and absolute errors were shown to be reduced substantially by the SPVA method. The method was especially successful in accounting for slice thickness and reconstruction kernel variations, where the median error was more than halved in comparison to the conventional approach.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2006.871547

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 288

Metadata

Authors
Kuhnigk, J.-M., Dicken, V., Bornemann, L., Bakai, A., Wormanns, D., Krass, S., & Peitgen, H.-O.
Venue
IEEE Transactions on Medical Imaging
Published
2006-04
Volume
25
Issue
4
Pages
417-434
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2161430726
Cited by
288
References
20
FWCI
18.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Morphological segmentation and partial volume analysis for volumetry of solid pulmonary lesions in thoracic CT scans. https://app.cochat.ai/papers/10.1109/tmi.2006.871547
The paper
Kuhnigk, J.-M., Dicken, V., Bornemann, L., Bakai, A., Wormanns, D., Krass, S., & Peitgen, H.-O. (2006). Morphological segmentation and partial volume analysis for volumetry of solid pulmonary lesions in thoracic CT scans. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2006.871547

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.