Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 237

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Image-processing technique for suppressing ribs in chest radiographs by means of massive training artificial neural network (MTANN)

Suzuki, K., Abe, H., MacMahon, H., Doi, K. · 2006 · IEEE Transactions on Medical Imaging

Abstract

When lung nodules overlap with ribs or clavicles in chest radiographs, it can be difficult for radiologists as well as computer-aided diagnostic (CAD) schemes to detect these nodules. In this paper, we developed an image-processing technique for suppressing the contrast of ribs and clavicles in chest radiographs by means of a multiresolution massive training artificial neural network (MTANN). An MTANN is a highly nonlinear filter that can be trained by use of input chest radiographs and the corresponding "teaching" images. We employed "bone" images obtained by use of a dual-energy subtraction technique as the teaching images. For effective suppression of ribs having various spatial frequencies, we developed a multiresolution MTANN consisting of multiresolution decomposition/composition techniques and three MTANNs for three different-resolution images. After training with input chest radiographs and the corresponding dual-energy bone images, the multiresolution MTANN was able to provide "bone-image-like" images which were similar to the teaching bone images. By subtracting the bone-image-like images from the corresponding chest radiographs, we were able to produce "soft-tissue-image-like" images where ribs and clavicles were substantially suppressed. We used a validation test database consisting of 118 chest radiographs with pulmonary nodules and an independent test database consisting of 136 digitized screen-film chest radiographs with 136 solitary pulmonary nodules collected from 14 medical institutions in this study. When our technique was applied to nontraining chest radiographs, ribs and clavicles in the chest radiographs were suppressed substantially, while the visibility of nodules and lung vessels was maintained. Thus, our image-processing technique for rib suppression by means of a multiresolution MTANN would be potentially useful for radiologists as well as for CAD schemes in detection of lung nodules on chest radiographs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2006.871549

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 237

Metadata

Authors
Suzuki, K., Abe, H., MacMahon, H., & Doi, K.
Venue
IEEE Transactions on Medical Imaging
Published
2006-04
Volume
25
Issue
4
Pages
406-416
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2137865578
Cited by
237
References
4
FWCI
7.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.