Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 199

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

MRI of Moving Subjects Using Multislice Snapshot Images With Volume Reconstruction (SVR): Application to Fetal, Neonatal, and Adult Brain Studies

Jiang, Shuzhou, Xue, Hui, Glover, Alan, Rutherford, Mary, Rueckert, Daniel, Hajnal, Joseph V. · 2007 · IEEE Transactions on Medical Imaging

Abstract

Motion degrades magnetic resonance (MR) images and prevents acquisition of self-consistent and high-quality volume images. A novel methodology, Snapshot magnetic resonance imaging (MRI) with Volume Reconstruction (SVR) has been developed for imaging moving subjects at high resolution and high signal-to-noise ratio (SNR). The method combines registered 2-D slices from sequential dynamic single-shot scans. The SVR approach requires that the anatomy in question is not changing shape or size and is moving at a rate that allows snapshot images to be acquired. After imaging the target volume repeatedly to guarantee sufficient sampling every where, a robust slice-to-volume registration method has been implemented that achieves alignment of each slice within 0.3 mm in the examples tested. Multilevel scattered interpolation has been used to obtain high-fidelity reconstruction with root-mean-square (rms) error that is less than the noise level in the images. The SVR method has been performed successfully for brain studies on subjects that cannot stay still, and in some cases were moving substantially during scanning. For example, awake neonates, deliberately moved adults and, especially, on fetuses, for which no conventional high-resolution 3-D method is currently available. Fine structure of the in-utero fetal brain is clearly revealed for the first time and substantial SNR improvement is realized by having many individually acquired slices contribute to each voxel in the reconstructed image.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2007.895456

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 199

Metadata

Authors
Jiang, S., Xue, H., Glover, A., Rutherford, M., Rueckert, D., & Hajnal, J. V.
Venue
IEEE Transactions on Medical Imaging
Published
2007-07
Volume
26
Issue
7
Pages
967-980
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2166966312
Cited by
199
References
2
FWCI
6.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MRI of Moving Subjects Using Multislice Snapshot Images With Volume Reconstruction (SVR): Application to Fetal, Neonatal, and Adult Brain Studies. https://app.cochat.ai/papers/10.1109/tmi.2007.895456
The paper
Jiang, S., Xue, H., Glover, A., Rutherford, M., Rueckert, D., & Hajnal, J. V. (2007). MRI of Moving Subjects Using Multislice Snapshot Images With Volume Reconstruction (SVR): Application to Fetal, Neonatal, and Adult Brain Studies. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2007.895456

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.