CoChat

Accelerating the Nonequispaced Fast Fourier Transform on Commodity Graphics Hardware

SØrensen, Thomas Sangild, Schaeffter, Tobias, Noe, Karsten Østergaard, Hansen, Michael Schacht · 2008 · IEEE Transactions on Medical Imaging
Cited by 104

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

We present a fast parallel algorithm to compute the nonequispaced fast Fourier transform on commodity graphics hardware (the GPU). We focus particularly on a novel implementation of the convolution step in the transform as it was previously its most time consuming part. We describe the performance for two common sample distributions in medical imaging (radial and spiral trajectories), and for different convolution kernels as these parameters all influence the speed of the algorithm. The GPU-accelerated convolution is up to 85 times faster as our reference, the open source NFFT library on a state-of-the-art 64 bit CPU. The accuracy of the proposed GPU implementation was quantitatively evaluated at the various settings. To illustrate the applicability of the transform in medical imaging, in which it is also known as gridding, we look specifically at non-Cartesian magnetic resonance imaging and reconstruct both a numerical phantom and an in vivo cardiac image.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2007.909834

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 104

Metadata

Authors
SØrensen, T. S., Schaeffter, T., Noe, K. Ø., & Hansen, M. S.
Venue
IEEE Transactions on Medical Imaging
Published
2008-04
Volume
27
Issue
4
Pages
538-547
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2157931750
Cited by
104
References
1
FWCI
23.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.