Respiratory Motion Correction in 3-D PET Data With Advanced Optical Flow Algorithms
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The problem of motion is well known in positron emission tomography (PET) studies. The PET images are formed over an elongated period of time. As the patients cannot hold breath during the PET acquisition, spatial blurring and motion artifacts are the natural result. These may lead to wrong quantification of the radioactive uptake. We present a solution to this problem by respiratory-gating the PET data and correcting the PET images for motion with optical flow algorithms. The algorithm is based on the combined local and global optical flow algorithm with modifications to allow for discontinuity preservation across organ boundaries and for application to 3-D volume sets. The superiority of the algorithm over previous work is demonstrated on software phantom and real patient data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Horn, B. K. P., & Schunck, B. G. (1981) · Artificial Intelligence · doi:10.1016/0004-3702(81)90024-2 · Cited by 10,312
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 1×
“Second, mutual information is sensitive to noise [38].”
Performance of optical flow techniques
Barron, J. L., Fleet, D. J., & Beauchemin, S. S. (1994) · International Journal of Computer Vision · doi:10.1007/bf01420984 · Cited by 4,305
Lucas/Kanade Meets Horn/Schunck: Combining Local and Global Optic Flow Methods
Bruhn, A., Weickert, J., & Schnörr, C. (2005) · International Journal of Computer Vision · doi:10.1023/b:visi.0000045324.43199.43 · Cited by 1,160
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946 · cited 1×
“This problem is enhanced in PET/CT scanners, which use the computed tomography (CT) data for attenuation correction [2].”
McCane, B., Novins, K., Crannitch, D., & Galvin, B. (2001) · Computer Vision and Image Understanding · doi:10.1006/cviu.2001.0930 · Cited by 250
Cited by
Castillo, R., Castillo, E., Guerra, R., Johnson, V. E., McPhail, T., Garg, A. K., & Guerrero, T. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/7/001 · Cited by 592
Metadata
- Authors
- Dawood, M., Buther, F., Jiang, X., & Schafers, K. P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2008-08
- Volume
- 27
- Issue
- 8
- Pages
- 1164-1175
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2119493793
- Cited by
- 179
- References
- 6
- FWCI
- 12.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Respiratory Motion Correction in 3-D PET Data With Advanced Optical Flow Algorithms. https://app.cochat.ai/papers/10.1109/tmi.2008.918321
- The paper
- Dawood, M., Buther, F., Jiang, X., & Schafers, K. P. (2008). Respiratory Motion Correction in 3-D PET Data With Advanced Optical Flow Algorithms. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2008.918321
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.