The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Computational Analysis and Improvement of SIRT
Abstract
Iterative X-ray computed tomography (CT) algorithms have the potential for producing high-quality images but are computationally very demanding, especially when applied to high-resolution problems. Focusing on simultaneous iterative reconstruction technique (SIRT), we provide an eigenvalue based scheme for automatically determining a near-optimal value of the relaxation parameter. This accelerates the convergence rate of SIRT to the point where only half the number of iterations normally required is needed. We also modify the way SIRT uses preconditioning to solve a weighted least squares problem. The resulting algorithm, which we call PSIRT, is associated with a smaller memory footprint and calls for less data to be communicated in a distributed-memory implementation. Experimental residual norm and timing results are provided based on cone-beam micro-CT mouse data, including for an ordered subsets study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Cited by
Fast and flexible X-ray tomography using the ASTRA toolbox
van Aarle, W., Palenstijn, W. J., Cant, J., Janssens, E., Bleichrodt, F., Dabravolski, A., De Beenhouwer, J., Joost Batenburg, K., & Sijbers, J. (2016) · Optics Express · doi:10.1364/oe.24.025129 · Cited by 1,036
The ASTRA Toolbox: A platform for advanced algorithm development in electron tomography
van Aarle, W., Palenstijn, W. J., De Beenhouwer, J., Altantzis, T., Bals, S., Batenburg, K. J., & Sijbers, J. (2015) · Ultramicroscopy · doi:10.1016/j.ultramic.2015.05.002 · Cited by 973
Palenstijn, W. J., Batenburg, K. J., & Sijbers, J. (2011) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.07.017 · Cited by 384
Successes and challenges in non-destructive testing of aircraft composite structures
TOWSYFYAN, H., BIGURI, A., BOARDMAN, R., & BLUMENSATH, T. (2020) · Chinese Journal of Aeronautics · doi:10.1016/j.cja.2019.09.017 · Cited by 272
Metadata
- Authors
- Gregor, J., & Benson, T.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2008-07
- Volume
- 27
- Issue
- 7
- Pages
- 918-924
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2112410684
- Cited by
- 206
- References
- 1
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computational Analysis and Improvement of SIRT. https://app.cochat.ai/papers/10.1109/tmi.2008.923696
- The paper
- Gregor, J., & Benson, T. (2008). Computational Analysis and Improvement of SIRT. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2008.923696
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.