Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 206

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Computational Analysis and Improvement of SIRT

Gregor, Jens, Benson, Thomas · 2008 · IEEE Transactions on Medical Imaging

Abstract

Iterative X-ray computed tomography (CT) algorithms have the potential for producing high-quality images but are computationally very demanding, especially when applied to high-resolution problems. Focusing on simultaneous iterative reconstruction technique (SIRT), we provide an eigenvalue based scheme for automatically determining a near-optimal value of the relaxation parameter. This accelerates the convergence rate of SIRT to the point where only half the number of iterations normally required is needed. We also modify the way SIRT uses preconditioning to solve a weighted least squares problem. The resulting algorithm, which we call PSIRT, is associated with a smaller memory footprint and calls for less data to be communicated in a distributed-memory implementation. Experimental residual norm and timing results are provided based on cone-beam micro-CT mouse data, including for an ordered subsets study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2008.923696

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 206

Metadata

Authors
Gregor, J., & Benson, T.
Venue
IEEE Transactions on Medical Imaging
Published
2008-07
Volume
27
Issue
7
Pages
918-924
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2112410684
Cited by
206
References
1
FWCI
4.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Computational Analysis and Improvement of SIRT. https://app.cochat.ai/papers/10.1109/tmi.2008.923696
The paper
Gregor, J., & Benson, T. (2008). Computational Analysis and Improvement of SIRT. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2008.923696

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.