The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Determination of Electric Conductivity and Local SAR Via B1 Mapping
Abstract
The electric conductivity can potentially be used as an additional diagnostic parameter, e.g., in tumor diagnosis. Moreover, the electric conductivity, in connection with the electric field, can be used to estimate the local SAR distribution during MR measurements. In this study, a new approach, called electric properties tomography (EPT) is presented. It derives the patient's electric conductivity, along with the corresponding electric fields, from the spatial sensitivity distributions of the applied RF coils, which are measured via MRI. Corresponding numerical simulations and initial experiments on a standard clinical MRI system underline the principal feasibility of EPT to determine the electric conductivity and the local SAR. In contrast to previous methods to measure the patient's electric properties, EPT does not apply externally mounted electrodes, currents, or RF probes, thus enhancing the practicality of the approach. Furthermore, in contrast to previous methods, EPT circumvents the solution of an inverse problem, which might lead to significantly higher spatial image resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
The dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
Yarnykh, V. L. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21120 · Cited by 1,026
Equations for Calculating the Dielectric Constant of Saline Water (Correspondence)
Stogryn, A. (1971) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.1971.1127617 · Cited by 872
The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz
Joines, W. T., Zhang, Y., Li, C., & Jirtle, R. L. (1994) · Medical Physics · doi:10.1118/1.597312 · Cited by 763
Dielectric properties of breast carcinoma and the surrounding tissues
Surowiec, A. J., Stuchly, S. S., Barr, J. R., & Swarup, A. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1374 · Cited by 736
Numerical Techniques in Electromagnetics, Second Edition
Sadiku, M. N. O. (2000) · Medical Entomology and Zoology · Cited by 633
Numerical Techniques in Electromagnetics
Sadiku, M. N. O. (2000) · CRC Press eBooks · doi:10.1201/9781420058277 · Cited by 552
Metadata
- Authors
- Katscher, U., Voigt, T., Findeklee, C., Vernickel, P., Nehrke, K., & DÖssel, O.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2009-09
- Volume
- 28
- Issue
- 9
- Pages
- 1365-1374
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2117026441
- Cited by
- 329
- References
- 20
- FWCI
- 8.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of Electric Conductivity and Local SAR Via B1 Mapping. https://app.cochat.ai/papers/10.1109/tmi.2009.2015757
- The paper
- Katscher, U., Voigt, T., Findeklee, C., Vernickel, P., Nehrke, K., & DÖssel, O. (2009). Determination of Electric Conductivity and Local SAR Via B1 Mapping. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2009.2015757
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.