The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
4-D Cardiac MR Image Analysis: Left and Right Ventricular Morphology and Function
Open accessAbstract
In this study, a combination of active shape model (ASM) and active appearance model (AAM) was used to segment the left and right ventricles of normal and Tetralogy of Fallot (TOF) hearts on 4-D (3-D+time) MR images. For each ventricle, a 4-D model was first used to achieve robust preliminary segmentation on all cardiac phases simultaneously and a 3-D model was then applied to each phase to improve local accuracy while maintaining the overall robustness of the 4-D segmentation. On 25 normal and 25 TOF hearts, in comparison to the expert traced independent standard, our comprehensive performance assessment showed subvoxel segmentation accuracy, high overlap ratios, good ventricular volume correlations, and small percent volume differences. Following 4-D segmentation, novel quantitative shape and motion features were extracted using shape information, volume-time and dV/dt curves, analyzed and used for disease status classification. Automated discrimination between normal/TOF subjects achieved 90%-100% sensitivity and specificity. The features obtained from TOF hearts show higher variability compared to normal subjects, suggesting their potential use as disease progression indicators. The abnormal shape and motion variations of the TOF hearts were accurately captured by both the segmentation and feature characterization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geva, T., Sandweiss, B. M., Gauvreau, K., Lock, J. E., & Powell, A. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.10.045 · Cited by 620
Cited by
A review of segmentation methods in short axis cardiac MR images
Petitjean, C., & Dacher, J.-N. (2011) · Medical Image Analysis · doi:10.1016/j.media.2010.12.004 · Cited by 737
Avendi, M. R., Kheradvar, A., & Jafarkhani, H. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.01.005 · Cited by 593
Khened, M., Kollerathu, V. A., & Krishnamurthi, G. (2019) · Medical Image Analysis · doi:10.1016/j.media.2018.10.004 · Cited by 373
Peng, P., Lekadir, K., Gooya, A., Shao, L., Petersen, S. E., & Frangi, A. F. (2016) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-015-0521-4 · Cited by 281
Statistical Shape Modeling of the Left Ventricle: Myocardial Infarct Classification Challenge
Suinesiaputra, A., Dhooge, J., Duchateau, N., Ehrhardt, J., Frangi, A. F., Gooya, A., Grau, V., Lekadir, K., Lu, A., Mukhopadhyay, A., et al. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2652449 · Cited by 95
Metadata
- Authors
- Zhang, H., Wahle, A., Johnson, R. K., Scholz, T. D., & Sonka, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2010-02
- Volume
- 29
- Issue
- 2
- Pages
- 350-364
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2146308017
- Cited by
- 165
- References
- 1
- FWCI
- 14.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 4-D Cardiac MR Image Analysis: Left and Right Ventricular Morphology and Function. https://app.cochat.ai/papers/10.1109/tmi.2009.2030799
- The paper
- Zhang, H., Wahle, A., Johnson, R. K., Scholz, T. D., & Sonka, M. (2010). 4-D Cardiac MR Image Analysis: Left and Right Ventricular Morphology and Function. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2009.2030799
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.