The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
3D Forward and Back-Projection for X-Ray CT Using Separable Footprints
Open accessAbstract
Iterative methods for 3D image reconstruction have the potential to improve image quality over conventional filtered back projection (FBP) in X-ray computed tomography (CT). However, the computation burden of 3D cone-beam forward and back-projectors is one of the greatest challenges facing practical adoption of iterative methods for X-ray CT. Moreover, projector accuracy is also important for iterative methods. This paper describes two new separable footprint (SF) projector methods that approximate the voxel footprint functions as 2D separable functions. Because of the separability of these footprint functions, calculating their integrals over a detector cell is greatly simplified and can be implemented efficiently. The SF-TR projector uses trapezoid functions in the transaxial direction and rectangular functions in the axial direction, whereas the SF-TT projector uses trapezoid functions in both directions. Simulations and experiments showed that both SF projector methods are more accurate than the distance-driven (DD) projector, which is a current state-of-the-art method in the field. The SF-TT projector is more accurate than the SF-TR projector for rays associated with large cone angles. The SF-TR projector has similar computation speed with the DD projector and the SF-TT projector is about two times slower.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Cited by
Iterative reconstruction methods in X-ray CT
Beister, M., Kolditz, D., & Kalender, W. A. (2012) · Physica Medica · doi:10.1016/j.ejmp.2012.01.003 · Cited by 751
A CUDA-based reverse gridding algorithm for MR reconstruction
Yang, J., Feng, C., & Zhao, D. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.038 · Cited by 16
Metadata
- Authors
- Long, Y., Fessler, J. A., & Balter, J. M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2010-11
- Volume
- 29
- Issue
- 11
- Pages
- 1839-1850
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2169010307
- Cited by
- 228
- References
- 1
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D Forward and Back-Projection for X-Ray CT Using Separable Footprints. https://app.cochat.ai/papers/10.1109/tmi.2010.2050898
- The paper
- Long, Y., Fessler, J. A., & Balter, J. M. (2010). 3D Forward and Back-Projection for X-Ray CT Using Separable Footprints. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2010.2050898
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.