X-Ray Luminescence Computed Tomography via Selective Excitation: A Feasibility Study

Open access
Pratx, Guillem, Carpenter, Colin M., Sun, Conroy, Xing, Lei·2010·IEEE Transactions on Medical Imaging

Abstract

X-ray luminescence computed tomography (XLCT) is proposed as a new molecular imaging modality based on the selective excitation and optical detection of X-ray-excitable phosphor nanoparticles. These nano-sized particles can be fabricated to emit near-infrared (NIR) light when excited with X-rays, and, because because both X-rays and NIR photons propagate long distances in tissue, they are particularly well suited for in vivo biomedical imaging. In XLCT, tomographic images are generated by irradiating the subject using a sequence of programmed X-ray beams, while sensitive photo-detectors measure the light diffusing out of the subject. By restricting the X-ray excitation to a single, narrow beam of radiation, the origin of the optical photons can be inferred regardless of where these photons were detected, and how many times they scattered in tissue. This study presents computer simulations exploring the feasibility of imaging small objects with XLCT, such as research animals. The accumulation of 50 nm phosphor nanoparticles in a 2-mm-diameter target can be detected and quantified with subpicomolar sensitivity using less than 1 cGy of radiation dose. Provided sufficient signal-to-noise ratio, the spatial resolution of the system can be made as high as needed by narrowing the beam aperture. In particular, 1 mm spatial resolution was achieved for a 1-mm-wide X-ray beam. By including an X-ray detector in the system, anatomical imaging is performed simultaneously with molecular imaging via standard X-ray computed tomography (CT). The molecular and anatomical images are spatially and temporally co-registered, and, if a single-pixel X-ray detector is used, they have matching spatial resolution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2010.2055883

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 170

Metadata

Authors
Pratx, G., Carpenter, C. M., Sun, C., & Xing, L.
Venue
IEEE Transactions on Medical Imaging
Published
2010-12
Volume
29
Issue
12
Pages
1992-1999
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2163131994
Cited by
170
References
2
FWCI
5.54
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: X-Ray Luminescence Computed Tomography via Selective Excitation: A Feasibility Study. https://app.cochat.ai/papers/10.1109/tmi.2010.2055883
The paper
Pratx, G., Carpenter, C. M., Sun, C., & Xing, L. (2010). X-Ray Luminescence Computed Tomography via Selective Excitation: A Feasibility Study. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2010.2055883

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.