On Combining Computer-Aided Detection Systems
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Computer-aided detection (CAD) is increasingly used in clinical practice and for many applications a multitude of CAD systems have been developed. In practice, CAD systems have different strengths and weaknesses and it is therefore interesting to consider their combination. In this paper, we present generic methods to combine multiple CAD systems and investigate what kind of performance increase can be expected. Experimental results are presented using data from the ANODE09 and ROC09 online CAD challenges for the detection of pulmonary nodules in computed tomography scans and red lesions in retinal images, respectively. For both applications, combination results in a large and significant increase in performance when compared to the best individual CAD system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Friedman, J., Hastie, T., & Tibshirani, R. (2000) · The Annals of Statistics · doi:10.1214/aos/1016218223 · Cited by 6,884 · cited 1×
“crease performance has been an accepted practice within the area of pattern recognition [2], [3] and forms the basis of established strategies such as boosting [4].”
BackgroundGiger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311 · cited 1×
“1 Many CAD systems are aimed at the detection of breast, lung, or colon cancer with X-ray, computed tomography (CT) or magnetic resonance imaging [1].”
Background
Cited by
Setio, A. A. A., Traverso, A., de Bel, T., Berens, M. S. N., Bogaard, C. V. D., Cerello, P., Chen, H., Dou, Q., Fantacci, M. E., Geurts, B., et al. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.06.015 · Cited by 1,374
Self-citationSetio, A. A. A., Ciompi, F., Litjens, G., Gerke, P., Jacobs, C., van Riel, S. J., Wille, M. M. W., Naqibullah, M., Sanchez, C. I., & van Ginneken, B. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2536809 · Cited by 1,258
“ROC curve (AUC) and 2) Competition Performance Metric (CPM) [28], which measures the average sensitivity at seven operating points of the FROC curve: 1/8, 1/4, 1/2, 1, 2, 4,”
BackgroundMultilevel Contextual 3-D CNNs for False Positive Reduction in Pulmonary Nodule Detection
Dou, Q., Chen, H., Yu, L., Qin, J., & Heng, P.-A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2613502 · Cited by 582
An Ensemble-Based System for Microaneurysm Detection and Diabetic Retinopathy Grading
Antal, B., & Hajdu, A. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2193126 · Cited by 335
Extraction of Airways From CT (EXACT'09)
Lo, P., van Ginneken, B., Reinhardt, J. M., Yavarna, T., de Jong, P. A., Irving, B., Fetita, C., Ortner, M., Pinho, R., Sijbers, J., et al. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2209674 · Cited by 290
Self-citation
Metadata
- Authors
- Niemeijer, M., Loog, M., Abràmoff, M. D., Viergever, M. A., Prokop, M., & van Ginneken, B.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2011-02
- Volume
- 30
- Issue
- 2
- Pages
- 215-223
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2105478370
- Cited by
- 130
- References
- 2
- FWCI
- 7.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On Combining Computer-Aided Detection Systems. https://app.cochat.ai/papers/10.1109/tmi.2010.2072789
- The paper
- Niemeijer, M., Loog, M., Abràmoff, M. D., Viergever, M. A., Prokop, M., & van Ginneken, B. (2011). On Combining Computer-Aided Detection Systems. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2010.2072789
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.