The DOI matches its Crossref record.
In Vivo Quantitative Mapping of Myocardial Stiffening and Transmural Anisotropy During the Cardiac Cycle
Abstract
Shear wave imaging was evaluated for the in vivo assessment of myocardial biomechanical properties on ten open chest sheep. The use of dedicated ultrasonic sequences implemented on a very high frame rate ultrasonic scanner ( > 5000 frames per second) enables the estimation of the quantitative shear modulus of myocardium several times during one cardiac cycle. A 128 element probe remotely generates a shear wave thanks to the radiation force induced by a focused ultrasonic burst. The resulting shear wave propagation is tracked using the same probe by cross-correlating successive ultrasonic images acquired at a very high frame rate. The shear wave speed estimated at each location in the ultrasonic image gives access to the local myocardial stiffness (shear modulus μ). The technique was found to be reproducible (standard deviation ) and able to estimate both systolic and diastolic stiffness on each sheep (respectively μ(dias) ≈ 2 kPa and μ(syst) ≈ 30 kPa). Moreover, the ability of the proposed method to polarize the shear wave generation and propagation along a chosen axis permits the study the local elastic anisotropy of myocardial muscle. As expected, myocardial elastic anisotropy is found to vary with muscle depth. The real time capabilities and potential of Shear Wave Imaging using ultrafast scanners for cardiac applications is finally illustrated by studying the dynamics of this fractional anisotropy during the cardiac cycle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Self-citationElastography for Muscle Biomechanics: Toward the Estimation of Individual Muscle Force
Hug, F., Tucker, K., Gennisson, J.-L., Tanter, M., & Nordez, A. (2015) · Exercise and Sport Sciences Reviews · doi:10.1249/jes.0000000000000049 · Cited by 342
Self-citationSăftoiu, A., Gilja, O. H., Sidhu, P. S., Dietrich, C. F., Cantisani, V., Amy, D., Bachmann-Nielsen, M., Bob, F., Bojunga, J., Brock, M., et al. (2019) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-0838-9937 · Cited by 320
Self-citationElastography imaging: the 30 year perspective
Ormachea, J., & Parker, K. J. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abca00 · Cited by 104
Metadata
- Authors
- Couade, M., Pernot, M., Messas, E., Bel, A., Ba, M., Hagege, A., Fink, M., & Tanter, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2011-02
- Volume
- 30
- Issue
- 2
- Pages
- 295-305
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2119759992
- Cited by
- 190
- References
- 0
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.