The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Parallel MR Image Reconstruction Using Augmented Lagrangian Methods
Open accessAbstract
Magnetic resonance image (MRI) reconstruction using SENSitivity Encoding (SENSE) requires regularization to suppress noise and aliasing effects. Edge-preserving and sparsity-based regularization criteria can improve image quality, but they demand computation-intensive nonlinear optimization. In this paper, we present novel methods for regularized MRI reconstruction from undersampled sensitivity encoded data--SENSE-reconstruction--using the augmented Lagrangian (AL) framework for solving large-scale constrained optimization problems. We first formulate regularized SENSE-reconstruction as an unconstrained optimization task and then convert it to a set of (equivalent) constrained problems using variable splitting. We then attack these constrained versions in an AL framework using an alternating minimization method, leading to algorithms that can be implemented easily. The proposed methods are applicable to a general class of regularizers that includes popular edge-preserving (e.g., total-variation) and sparsity-promoting (e.g., l(1)-norm of wavelet coefficients) criteria and combinations thereof. Numerical experiments with synthetic and in vivo human data illustrate that the proposed AL algorithms converge faster than both general-purpose optimization algorithms such as nonlinear conjugate gradient (NCG) and state-of-the-art MFISTA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse Problems
Beck, A., & Teboulle, M. (2009) · SIAM Journal on Imaging Sciences · doi:10.1137/080716542 · Cited by 11,952
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
A New Alternating Minimization Algorithm for Total Variation Image Reconstruction
Wang, Y., Yang, J., Yin, W., & Zhang, Y. (2008) · SIAM Journal on Imaging Sciences · doi:10.1137/080724265 · Cited by 1,975
Cited by
Plug-and-Play priors for model based reconstruction
Venkatakrishnan, S. V., Bouman, C. A., & Wohlberg, B. (2013) · 2013 IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2013.6737048 · Cited by 1,178
CNN-Based Projected Gradient Descent for Consistent CT Image Reconstruction
Gupta, H., Jin, K. H., Nguyen, H. Q., McCann, M. T., & Unser, M. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2832656 · Cited by 380
A Splitting-Based Iterative Algorithm for Accelerated Statistical X-Ray CT Reconstruction
Ramani, S., & Fessler, J. A. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2175233 · Cited by 257
Self-citation
Metadata
- Authors
- Ramani, S., & Fessler, J. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2011-03
- Volume
- 30
- Issue
- 3
- Pages
- 694-706
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2142808775
- Cited by
- 227
- References
- 3
- FWCI
- 9.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Parallel MR Image Reconstruction Using Augmented Lagrangian Methods. https://app.cochat.ai/papers/10.1109/tmi.2010.2093536
- The paper
- Ramani, S., & Fessler, J. A. (2011). Parallel MR Image Reconstruction Using Augmented Lagrangian Methods. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2010.2093536
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.