Texture-Based Analysis of COPD: A Data-Driven Approach
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This study presents a fully automatic, data-driven approach for texture-based quantitative analysis of chronic obstructive pulmonary disease (COPD) in pulmonary computed tomography (CT) images. The approach uses supervised learning where the class labels are, in contrast to previous work, based on measured lung function instead of on manually annotated regions of interest (ROIs). A quantitative measure of COPD is obtained by fusing COPD probabilities computed in ROIs within the lung fields where the individual ROI probabilities are computed using a k nearest neighbor (kNN ) classifier. The distance between two ROIs in the kNN classifier is computed as the textural dissimilarity between the ROIs, where the ROI texture is described by histograms of filter responses from a multi-scale, rotation invariant Gaussian filter bank. The method was trained on 400 images from a lung cancer screening trial and subsequently applied to classify 200 independent images from the same screening trial. The texture-based measure was significantly better at discriminating between subjects with and without COPD than were the two most common quantitative measures of COPD in the literature, which are based on density. The proposed measure achieved an area under the receiver operating characteristic curve (AUC) of 0.713 whereas the best performing density measure achieved an AUC of 0.598. Further, the proposed measure is as reproducible as the density measures, and there were indications that it correlates better with lung function and is less influenced by inspiration level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparative study of texture measures with classification based on featured distributions
Ojala, T., Pietikäinen, M., & Harwood, D. (1996) · Pattern Recognition · doi:10.1016/0031-3203(95)00067-4 · Cited by 6,882 · cited 2×
“The bin widths are derived using adaptive binning [22].”
MethodRabe, K. F., Hurd, S., Anzueto, A., Barnes, P. J., Buist, S. A., Calverley, P., Fukuchi, Y., Jenkins, C., Rodriguez-Roisin, R., van Weel, C., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200703-456so · Cited by 4,925
Cited by
Larue, R. T. H. M., Defraene, G., De Ruysscher, D., Lambin, P., & van Elmpt, W. (2017) · The British Journal of Radiology · doi:10.1259/bjr.20160665 · Cited by 363
Machine learning approaches in medical image analysis: From detection to diagnosis
de Bruijne, M. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.06.032 · Cited by 347
Self-citationDisease Staging and Prognosis in Smokers Using Deep Learning in Chest Computed Tomography
González, G., Ash, S. Y., Vegas-Sánchez-Ferrero, G., Onieva Onieva, J., Rahaghi, F. N., Ross, J. C., Díaz, A., San José Estépar, R., & Washko, G. R. (2018) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201705-0860oc · Cited by 281
Sørensen, L., Igel, C., Pai, A., Balas, I., Anker, C., Lillholm, M., & Nielsen, M. (2017) · NeuroImage: Clinical · doi:10.1016/j.nicl.2016.11.025 · Cited by 179
Self-citationFeature-Based Image Patch Approximation for Lung Tissue Classification
Song, Y., Cai, W., Zhou, Y., & Feng, D. D. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2241448 · Cited by 177
Metadata
- Authors
- Sorensen, L., Nielsen, M., Lo, P., Ashraf, H., Pedersen, J. H., & de Bruijne, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2012-01
- Volume
- 31
- Issue
- 1
- Pages
- 70-78
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2044769820
- Cited by
- 83
- References
- 2
- FWCI
- 3.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.