Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 159

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Evaluation of Three MRI-Based Anatomical Priors for Quantitative PET Brain Imaging

Vunckx, K., Atre, A., Baete, K., Reilhac, A., Deroose, C. M., Van Laere, K., Nuyts, J. · 2012 · IEEE Transactions on Medical Imaging

Abstract

In emission tomography, image reconstruction and therefore also tracer development and diagnosis may benefit from the use of anatomical side information obtained with other imaging modalities in the same subject, as it helps to correct for the partial volume effect. One way to implement this, is to use the anatomical image for defining the a priori distribution in a maximum-a-posteriori (MAP) reconstruction algorithm. In this contribution, we use the PET-SORTEO Monte Carlo simulator to evaluate the quantitative accuracy reached by three different anatomical priors when reconstructing positron emission tomography (PET) brain images, using volumetric magnetic resonance imaging (MRI) to provide the anatomical information. The priors are: 1) a prior especially developed for FDG PET brain imaging, which relies on a segmentation of the MR-image (Baete , 2004); 2) the joint entropy-prior (Nuyts, 2007); 3) a prior that encourages smoothness within a position dependent neighborhood, computed from the MR-image. The latter prior was recently proposed by our group in (Vunckx and Nuyts, 2010), and was based on the prior presented by Bowsher (2004). The two latter priors do not rely on an explicit segmentation, which makes them more generally applicable than a segmentation-based prior. All three priors produced a compromise between noise and bias that was clearly better than that obtained with postsmoothed maximum likelihood expectation maximization (MLEM) or MAP with a relative difference prior. The performance of the joint entropy prior was slightly worse than that of the other two priors. The performance of the segmentation-based prior is quite sensitive to the accuracy of the segmentation. In contrast to the joint entropy-prior, the Bowsher-prior is easily tuned and does not suffer from convergence problems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2011.2173766

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 159

Metadata

Authors
Vunckx, K., Atre, A., Baete, K., Reilhac, A., Deroose, C. M., Van Laere, K., & Nuyts, J.
Venue
IEEE Transactions on Medical Imaging
Published
2012-03
Volume
31
Issue
3
Pages
599-612
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2037922117
Cited by
159
References
1
FWCI
8.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Three MRI-Based Anatomical Priors for Quantitative PET Brain Imaging. https://app.cochat.ai/papers/10.1109/tmi.2011.2173766
The paper
Vunckx, K., Atre, A., Baete, K., Reilhac, A., Deroose, C. M., Van Laere, K., & Nuyts, J. (2012). Evaluation of Three MRI-Based Anatomical Priors for Quantitative PET Brain Imaging. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2011.2173766

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.