Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 248

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Analysis of Co-Occurrence Texture Statistics as a Function of Gray-Level Quantization for Classifying Breast Ultrasound

Gomez, W., Pereira, W. C. A., Infantosi, A. F. C. · 2012 · IEEE Transactions on Medical Imaging

Abstract

In this paper, we investigated the behavior of 22 co-occurrence statistics combined to six gray-scale quantization levels to classify breast lesions on ultrasound (BUS) images. The database of 436 BUS images used in this investigation was formed by 217 carcinoma and 219 benign lesions images. The region delimited by a minimum bounding rectangle around the lesion was employed to calculate the gray-level co-occurrence matrix (GLCM). Next, 22 co-occurrence statistics were computed regarding six quantization levels (8, 16, 32, 64, 128, and 256), four orientations (0° , 45° , 90° , and 135°), and ten distances (1, 2,...,10 pixels). Also, to reduce feature space dimensionality, texture descriptors of the same distance were averaged over all orientations, which is a common practice in the literature. Thereafter, the feature space was ranked using mutual information technique with minimal-redundancy-maximal-relevance (mRMR) criterion. Fisher linear discriminant analysis (FLDA) was applied to assess the discrimination power of texture features, by adding the first m-ranked features to the classification procedure iteratively until all of them were considered. The area under ROC curve (AUC) was used as figure of merit to measure the performance of the classifier. It was observed that averaging texture descriptors of a same distance impacts negatively the classification performance, since the best AUC of 0.81 was achieved with 32 gray levels and 109 features. On the other hand, regarding the single texture features (i.e., without averaging procedure), the quantization level does not impact the discrimination power, since AUC = 0.87 was obtained for the six quantization levels. Moreover, the number of features was reduced (between 17 and 24 features). The texture descriptors that contributed notably to distinguish breast lesions were contrast and correlation computed from GLCMs with orientation of 90° and distance more than five pixels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2012.2206398

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 248

Metadata

Authors
Gomez, W., Pereira, W. C. A., & Infantosi, A. F. C.
Venue
IEEE Transactions on Medical Imaging
Published
2012-10
Volume
31
Issue
10
Pages
1889-1899
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2105184687
Cited by
248
References
1
FWCI
7.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis of Co-Occurrence Texture Statistics as a Function of Gray-Level Quantization for Classifying Breast Ultrasound. https://app.cochat.ai/papers/10.1109/tmi.2012.2206398
The paper
Gomez, W., Pereira, W. C. A., & Infantosi, A. F. C. (2012). Analysis of Co-Occurrence Texture Statistics as a Function of Gray-Level Quantization for Classifying Breast Ultrasound. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2012.2206398

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.