Attenuation Correction for the HRRT PET-Scanner Using Transmission Scatter Correction and Total Variation Regularization
Open accessThe DOI matches its Crossref record.
Abstract
UNLABELLED: In the standard software for the Siemens high-resolution research tomograph (HRRT) positron emission tomography (PET) scanner the most commonly used segmentation in the μ -map reconstruction for human brain scans is maximum a posteriori for transmission (MAP-TR). Bias in the lower cerebellum and pons in HRRT brain images have been reported. The two main sources of the problem with MAP-TR are poor bone/soft tissue segmentation below the brain and overestimation of bone mass in the skull. METHOD: We developed the new transmission processing with total variation (TXTV) method that introduces scatter correction in the μ-map reconstruction and total variation filtering to the transmission processing. RESULTS: Comparing MAP-TR and the new TXTV with gold standard CT-based attenuation correction, we found that TXTV has less bias as compared to MAP-TR. We also compared images acquired at the HRRT scanner using TXTV to the GE Advance scanner images and found high quantitative correspondence. TXTV has been used to reconstruct more than 4000 HRRT scans at seven different sites with no reports of biases. CONCLUSION: TXTV-based reconstruction is recommended for human brain scans on the HRRT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Johansen, A., Armand, S., Plavén-Sigray, P., Nasser, A., Ozenne, B., Petersen, I. N., Keller, S. H., Madsen, J., Beliveau, V., Møller, K., et al. (2023) · Molecular Psychiatry · doi:10.1038/s41380-023-02285-8 · Cited by 53
Self-citationEscitalopram increases synaptic density in the human brain over weeks: A randomized controlled trial
(2023) · doi:10.21203/rs.3.rs-2989150/v1 · Cited by 53
Raval, N. R., Gudmundsen, F., Juhl, M., Andersen, I. V., Speth, N., Videbæk, A., Petersen, I. N., Mikkelsen, J. D., Fisher, P. M., Herth, M. M., et al. (2021) · Frontiers in Synaptic Neuroscience · doi:10.3389/fnsyn.2021.715811 · Cited by 22
Evaluation of in vivo staging of amyloid deposition in cognitively unimpaired elderly aged 78–94
Michalowska, M. M., Herholz, K., Hinz, R., Amadi, C., McInnes, L., Anton-Rodriguez, J. M., Karikari, T. K., Blennow, K., Zetterberg, H., Ashton, N. J., et al. (2022) · Molecular Psychiatry · doi:10.1038/s41380-022-01685-6 · Cited by 11
“A 7min transmission scan using a 137Cs point source was acquired for attenuation and scatter correction [22, 23].”
Method
Metadata
- Authors
- Keller, S. H., Svarer, C., & Sibomana, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2013-09
- Volume
- 32
- Issue
- 9
- Pages
- 1611-1621
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2096147487
- Cited by
- 56
- References
- 0
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Attenuation Correction for the HRRT PET-Scanner Using Transmission Scatter Correction and Total Variation Regularization. https://app.cochat.ai/papers/10.1109/tmi.2013.2261313
- The paper
- Keller, S. H., Svarer, C., & Sibomana, M. (2013). Attenuation Correction for the HRRT PET-Scanner Using Transmission Scatter Correction and Total Variation Regularization. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2013.2261313
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.