CoChat

Robust Texture Analysis Using Multi-Resolution Gray-Scale Invariant Features for Breast Sonographic Tumor Diagnosis

Yang, Min-Chun, Moon, Woo Kyung, Wang, Yu-Chiang Frank, Bae, Min Sun, Huang, Chiun-Sheng, Chen, Jeon-Hor, Chang, Ruey-Feng · 2013 · IEEE Transactions on Medical Imaging
Cited by 97

The DOI matches its Crossref record.

Abstract

Computer-aided diagnosis (CAD) systems in gray-scale breast ultrasound images have the potential to reduce unnecessary biopsy of breast masses. The purpose of our study is to develop a robust CAD system based on the texture analysis. First, gray-scale invariant features are extracted from ultrasound images via multi-resolution ranklet transform. Thus, one can apply linear support vector machines (SVMs) on the resulting gray-level co-occurrence matrix (GLCM)-based texture features for discriminating the benign and malignant masses. To verify the effectiveness and robustness of the proposed texture analysis, breast ultrasound images obtained from three different platforms are evaluated based on cross-platform training/testing and leave-one-out cross-validation (LOO-CV) schemes. We compare our proposed features with those extracted by wavelet transform in terms of receiver operating characteristic (ROC) analysis. The AUC values derived from the area under the curve for the three databases via ranklet transform are 0.918 (95% confidence interval [CI], 0.848 to 0.961), 0.943 (95% CI, 0.906 to 0.968), and 0.934 (95% CI, 0.883 to 0.961), respectively, while those via wavelet transform are 0.847 (95% CI, 0.762 to 0.910), 0.922 (95% CI, 0.878 to 0.958), and 0.867 (95% CI, 0.798 to 0.914), respectively. Experiments with cross-platform training/testing scheme between each database reveal that the diagnostic performance of our texture analysis using ranklet transform is less sensitive to the sonographic ultrasound platforms. Also, we adopt several co-occurrence statistics in terms of quantization levels and orientations (i.e., descriptor settings) for computing the co-occurrence matrices with 0.632+ bootstrap estimators to verify the use of the proposed texture analysis. These experiments suggest that the texture analysis using multi-resolution gray-scale invariant features via ranklet transform is useful for designing a robust CAD system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2013.2279938

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 97

Metadata

Authors
Yang, M.-C., Moon, W. K., Wang, Y.-C. F., Bae, M. S., Huang, C.-S., Chen, J.-H., & Chang, R.-F.
Venue
IEEE Transactions on Medical Imaging
Published
2013-12
Volume
32
Issue
12
Pages
2262-2273
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2060766460
Cited by
97
References
0
FWCI
8.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Robust Texture Analysis Using Multi-Resolution Gray-Scale Invariant Features for Breast Sonographic Tumor Diagnosis. https://app.cochat.ai/papers/10.1109/tmi.2013.2279938
The paper
Yang, M.-C., Moon, W. K., Wang, Y.-C. F., Bae, M. S., Huang, C.-S., Chen, J.-H., & Chang, R.-F. (2013). Robust Texture Analysis Using Multi-Resolution Gray-Scale Invariant Features for Breast Sonographic Tumor Diagnosis. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2013.2279938

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.